Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V,5V
99W
3.5A,3A
88-132Vac, 176-264Vac (Selectable by Switch)
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.42 kg (0.93 lb)
** NRND **
PMT-D2V100W1AA, PMT-D2V100W1AG, PMT-D2V100W1AAB
** Discontinued Product **
PMT-D2V100W1AH
| Model | Description |
|---|---|
| PMT-D2V100W1AG | Enclosed, front face connector |
| PMT-D2V100W1AH | Enclosed, harness connector |
| PMT-D2V100W1AAB | Enclosed, terminal block, conformal coating |
** NRND **
PMT-D2V100W1AA, PMT-D2V100W1AG, PMT-D2V100W1AAB
** Discontinued Product **
PMT-D2V100W1AH
24V,5V
99W
3.5A,3A
88-132Vac, 176-264Vac (Selectable by Switch)
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.42 kg (0.93 lb)
| Model | Description |
|---|---|
| PMT-D2V100W1AG | Enclosed, front face connector |
| PMT-D2V100W1AH | Enclosed, harness connector |
| PMT-D2V100W1AAB | Enclosed, terminal block, conformal coating |
|
Output Current
3.5A,3A
|
|
Output Voltage
24V,5V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
V1: 21.6-26.4Vdc
|
|
Output Power
99W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5% typ. (@ 100-132Vac & 200-264Vac)
|
|
Load Regulation
V1: ± 1% typ. (@ 100-132Vac & 200-264Vac )
V2: ± 2% typ. (@ 100-132Vac & 200-264Vac ) |
|
PARD
V1: < 120mVpp,
V2: < 80mVpp |
|
Start-up Time
< 1200ms @ 115Vac,
< 2000ms @ 230Vac (100% load) |
|
Hold-up Time
> 20ms @ 115Vac,
> 25ms @ 230Vac |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load
|
|
Start-up with Capacitive Loads
8,000μF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-120Vac, 200-240Vac (Selectable by Switch)
|
|
Input Voltage Range
88-132Vac, 176-264Vac (Selectable by Switch)
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 2.00A@115Vac,
< 1.20A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 84.0% typ. @ 230Vac
|
|
Inrush Current
< 45A typ. @ 230Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 0.25mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium / SGCC
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.42 kg (0.93 lb)
|
Dimensions
178 x 97 x
38 mm
7.01” x 3.82” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 0.8% / 1V |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
-
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
V1: 115-135%, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Overload / Overcurrent
V1: 110-150%, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 100Vac, O/P: 100% load, Ta: 35°C |
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart: EN 60950-1 / EN62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) I CB Scheme :EC 60950-1 / IEC 62368-1 CCC: GB 4943.1 (for PMT-D2100W1AA) |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac Output to Ground: 0.5 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
CISPR 32, EN/BS EN 55032, FCC Title 47: Class B
|
|
Immunity
EN/BS EN 55024
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
12V
2500W
0-208.3A
85-264 Vac
48V
600W
12.5A
90-132Vac, 180-
48V
2500W
0-52.1A
85-264 Vac
24V
600W
25A
90-132Vac, 180-
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.