48V
2000W
41.6A
80 - 275 Vac
309.6 x 127 x 40.6 mm
12.19” x 5.00” x 1.60”
2 kg (4.41 lb)
48V
2000W
41.6A
80 - 275 Vac
309.6 x 127 x 40.6 mm
12.19” x 5.00” x 1.60”
2 kg (4.41 lb)
|
Output Current
41.6A
|
|
Output Voltage
48V
|
|
Output Voltage Range
48Vdc
|
|
Output Voltage Adjustment Range
38.4 V – 57.6 V
|
|
Output Power
2000W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
20 ms
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
10,000 μF
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
< 480 mV
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 200 ms
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100 - 240 Vac
|
|
Input Voltage Range
80 - 275 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50 - 60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
120 - 300 Vdc
|
|
Input Current
17.2 A @ 80 Vac
12 A @ 120 Vdc |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
-
|
|
Inrush Current
< 25 A
|
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.97 (typical)
|
|
Leakage Current
AC Leakage current from Input to earth ground
AC Leakage current from Output to earth ground |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
-
|
|
|
Indicator
Green LED
|
|
|
Cooling System
2 fans with variable speed control
|
|
|
Input Terminal
Block M4 x 3 pins
|
|
|
Output Terminal
Block M5 x 2 pins
|
|
|
Signal Terminal
Connector x 14 pins
|
|
|
Noise Sound Pressure Level (SPL)
< 39 dB(A)
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
2 kg (4.41 lb)
|
Dimensions
309.6 x 127 x
40.6 mm
12.19” x 5.00” x 1.60” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-20 °C to +70 °C (-4°F to +158 °F)
|
|
Storage Temperature
-40 °C to +85 °C (-40 °F to +185 °F)
|
|
Power De-rating
When AC input voltage is < 110 Vac, the output power is reduced by 20 W per 1 V.
|
|
Operating Humidity
-
|
|
Shock Test (Non-Operating)
IEC 60068-2-27 compliant, 50 g, 11 ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
IEC 60068-2-6 compliant, 2.09 Grms, 5 - 500 Hz, 20 minutes per side (3 planes)
|
|
Storage Humidity
-
|
|
Operating Altitude
5000 m (54kPa)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
YES, latch mode
58 V to 61 V |
|
Overload / Overcurrent
3000 W for over 750 ms max
Standby 3.2 A max with Hiccup Mode (Non-Latching, Auto-Recovery) |
|
Over Temperature
YES, auto recovery
|
|
Short Circuit
YES, auto recovery
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
Safety Certificate
IEC 62368 Edition 2:
IEC 62368-1 (2014) Edition 2 5000 m (16,400 ft) altitude, 120 V to 300 Vdc and 100 V to 240±10% Vac IEC/EN 60950-1, Edition 2 and all national deviations: UL 60950-1/CSA 22.2 No 60950-1, Edition 2; UL 62368-1 5000 m (16,400 ft) altitude, 120 V to 300 Vdc and 100 V to 240 ±10% Vac (UL File E135494) IEC/EN 60601-1, Edition 3: IEC 60601-1(2005), EN60601-1(2006) ANSI/AAMI ES 60601-1(2005) CAN/CSA C22.2 No. 60601-1 (2008); 3,000 m (9,800 ft) altitude, 100 V to 240 Vac ±10% IEC 60601-1-2 Edition 4: IEC 60601-1-2 (2014) |
|
Electrical Safety
-
|
|
CE
-
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
EN 55032, EN 55032 and FCC, Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
EN 61000-3-3
|
|
ESD Immunity
EN 61000-4-2, level 4, 8 kV contact, 15 kV air
|
|
Radiated Immunity
EN 61000-4-3, level 3, 12 V/m
|
|
EFT
EN 61000-4-4, level 4, ±2 kV
|
|
Surge
EN 61000-4-5, level 4, 1 kV DM, 2 kV CM
|
|
Conducted Immunity
EN 61000-4-6, level 3, 10 Vrms
|
|
Magnetic Field
EN 61000-4-8, level 3, 10 A/m
|
|
Voltage Dips
EN 61000-4-11, 30%, 20 ms - R&D
EN 61000-4-11, 60%, 100 ms EN 61000-4-11, 100%, 500 ms EN 60601-1-2:2015 (4th edition), 30%, 500 ms EN 60601-1-2:2015 (4th edition), 60%, 100 ms EN 60601-1-2:2015 (4th edition), 100%, 20 ms EN 60601-1-2:2015 (4th edition), 100%, 5000 ms |
|
Component Power Supply for General Use
-
|
24V
1200W
0-50A
85-264 Vac
48V
1000W
21A
90-264 Vac
24V
1500W
62.5A
90-264 Vac
24V
1000W
42A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.