Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
4.2V
231W
55A
85-264Vac
215 x 115 x 50 mm
8.46” x 4.53” x 1.97”
0.86 kg (1.90 lb)
** NRND **
PMF-4V320WCGB, PMF-4V320WCGR, PMF-4V320WCAB, PMF-4V320WCAR
Recommended Model: PMR-4V320WDAA
| Model | Description |
|---|---|
| PMF-4V320WCGR | Front face connector, remote ON/OFF |
| PMF-4V320WCAB | Terminal block |
| PMF-4V320WCAR | Terminal block, remote ON/OFF |
** NRND **
PMF-4V320WCGB, PMF-4V320WCGR, PMF-4V320WCAB, PMF-4V320WCAR
Recommended Model: PMR-4V320WDAA
4.2V
231W
55A
85-264Vac
215 x 115 x 50 mm
8.46” x 4.53” x 1.97”
0.86 kg (1.90 lb)
| Model | Description |
|---|---|
| PMF-4V320WCGR | Front face connector, remote ON/OFF |
| PMF-4V320WCAB | Terminal block |
| PMF-4V320WCAR | Terminal block, remote ON/OFF |
|
Output Current
55A
|
|
Output Voltage
4.2V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
3.78-4.62Vdc
|
|
Output Power
231W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5% typ. (@ 115Vac & 230Vac)
|
|
Load Regulation
± 1.5% typ. (@ 115Vac & 230Vac)
|
|
PARD
< 150mVpp@ 25°C
< 300mVpp @ -10°C |
|
Start-up Time
2500ms typ. @ 115Vac,
1000ms typ. @ 230Vac (100% load) |
|
Hold-up Time
16ms typ. @ 115Vac & 230Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% (0.5V pk-pk) @ 115Vac & 230Vac (0-50% load and 50-100% load)
(Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz) |
|
Start-up with Capacitive Loads
8,000μF Max
|
|
Remote ON/OFF
CN102
Output ON: 5-12.5 V Output OFF: 0-0.5 V |
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
50ms typ. @ 115Vac & 230Vac (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 5.00A@115Vac, < 2.50A @ 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
76.5% typ. @ 230Vac
|
|
Inrush Current
(Cold Start)
< 20A @ 115Vac, < 40A @ 230Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
0.97 typ. @ 115Vac, 0.94 typ. @ 230Vac
|
|
Leakage Current
< 1mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
0% load: 3.43W typ. @ 115Vac & 3.25W typ. @ 230Vac
100% load: 79.68 typ. @ 115Vac & 71.72 typ. @ 230Vac |
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Forced Cooling
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
<60dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
AWG 14-12
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.86 kg (1.90 lb)
|
Dimensions
215 x 115 x
50 mm
8.46” x 4.53” x 1.97” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C (Cold start at -20°C)
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 90Vac de-rate power by 5% / 1V |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters(16,400 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
4.83-6.50V, Latch Mode
|
|
Overload / Overcurrent
105-135%, Hiccup Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 100Vac, O/P: 100% load, Ta: 35°C |
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart : EN 60950-1, EN62368-1
UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) CB scheme : IEC 60950-1, IEC 62368-1 CCC: GB4943.1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 2.0 KVac Output to Ground: 0.5 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV (EN 60950-1)
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016
and Electrical Equipment (Safety) Regulations 2016 |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
CISPR 32, EN/BS EN 55032, FCC Title 47: Class B
|
|
Immunity
EN/BS EN 55024
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A and Class D
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
150W
6.25A
180-264 Vac
24V
108W
4.5A
180-264 Vac
24V
750W
-
85-264 Vac
48V
150W
3.3A
90-264 Vac