Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
50W
2.1A
85-264Vac
98 x 97 x 38 mm
3.86” x 3.82” x 1.50”
0.21 kg (0.46 lb)
** NRND **
PMH-24V50WCAA, PMH-24V50WCAT, PMH-24V50WCAH, PMH-24V50WCAS
** Discontinued Product **
PMH-24V50WCAJ, PMH-24V50WCAL, PMH-24V50WCAU, PMH-24V50WCAV
Recommended Model: PMT-24V50W2BA
| Model | Description |
|---|---|
| PMH-24V50WCAH | Harness connector, output non-isolated to PE |
| PMH-24V50WCAS | Terminal block, output isolated to PE |
| PMH-24V50WCAT | Harness connector, output isolated to PE |
** NRND **
PMH-24V50WCAA, PMH-24V50WCAT, PMH-24V50WCAH, PMH-24V50WCAS
** Discontinued Product **
PMH-24V50WCAJ, PMH-24V50WCAL, PMH-24V50WCAU, PMH-24V50WCAV
Recommended Model: PMT-24V50W2BA
24V
50W
2.1A
85-264Vac
98 x 97 x 38 mm
3.86” x 3.82” x 1.50”
0.21 kg (0.46 lb)
| Model | Description |
|---|---|
| PMH-24V50WCAH | Harness connector, output non-isolated to PE |
| PMH-24V50WCAS | Terminal block, output isolated to PE |
| PMH-24V50WCAT | Harness connector, output isolated to PE |
|
Output Current
2.1A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
22-28Vdc
|
|
Output Power
50W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5% (@ 85-264Vac input, 100% load)
|
|
Load Regulation
< 0.5% (@ 85-264Vac input, 0-100% load)
|
|
PARD
< 100mVpp @ -20°C to 70°C
< 150mVpp @ < -20°C to -30°C |
|
Start-up Time
< 800ms @ nominal input (100% load)
|
|
Hold-up Time
> 15ms @ 115Vac, > 90ms @ 230Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 0-100% load
(Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 100Hz) |
|
Start-up with Capacitive Loads
8,000µF Max
(@ > -20°C, 85-264Vac input & @ ≤ -20°C, 100-264Vac input) |
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
125-250Vdc
|
|
DC Input Voltage Range
120-375Vdc
|
|
Input Current
< 0.94A @ 115Vac, < 0.59A @ 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 87.0% @ 115Vac, > 88.0% 230Vac
|
|
Inrush Current
< 35A @ 115Vac, < 70A @ 230Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 0.5mA @ 264Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.21 kg (0.46 lb)
|
Dimensions
98 x 97 x
38 mm
3.86” x 3.82” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-30°C to +70°C
|
|
Storage Temperature
-30°C to +85°C
|
|
Power De-rating
-20°C to -30°C de-rate power by 2.0% / °C
> 50°C de-rate power by 2.5% / °C |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,1 times per direction, 2 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak);
displacement of 0.35mm; 20 min per axis for all X, Y, Z direction |
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
28.8-35.2V range, Hiccup Mode,
Non-Latching (Auto-Recovery) |
|
Overload / Overcurrent
> 120% of rated load current, Hicc-up Mode, Non-Latching (Auto recovery)
|
|
Over Temperature
< 75°C Ambient Temp@ 100% load, Non-Latching (Auto-recovery)
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
IP20 (PMH-24V50WCAJ and PMH-24V50WCAU)
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs, as per per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C |
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
SIQ Bauart: EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16, IEC 62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 5.0KVac
Input to Ground: 1.5KVac Output to Ground: Output non-isolated to PE (common pins connect to PE) (PMH-24V50WCAA, PMH-24V50WCAJ, PMH-24V50WCAL, PMH-24V50WCAH) 1.5KVdc (Output isolated to PE) (PMH-24V50WCAS, PMH-24V50WCAU, PMH-24V50WCAV, PMH-24V50WCAT) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
Output non-isolated to PE: PELV (EN 60335), SELV (EN 60950)
Output isolated to PE: SELV (EN 60335), SELV (EN 60950) |
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032, FCC Title 47: Class B, EN/BS EN 55014-1, EN/BS EN 61000-6-3
|
|
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-1, EN/BS EN 55014-2
|
|
Harmonic Current Emissions
-
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
48V
211.2W
4.4A
180-264 Vac
48V
1200W
-
85-264 Vac
12V
150W
12.5A
90-264 Vac
24V
1200W
-
85-264 Vac