Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
150-550V
1200W
2A
187-528 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
150-550V
1200W
2A
187-528 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
|
Output Current
2A
|
|
Output Voltage
150-550V
|
|
Output Voltage Range
150-550Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
1200W
|
|
Output Current Adjustment Range
0.7-2A
|
|
Max Output Voltage
550Vdc
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
208-480 Vac
|
|
Input Voltage Range
187-528 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50/60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
5.7A At 220Vac, 25°C, 500V/1.2A @ Pout=1200W
2.6A At 480Vac, 25°C, 500V/1.2A @ Pout=1200W |
|
Input Power (Standby Mode)
0.5W At 230Vac/50Hz, Output and DALI bus power supply are in OFF status,
in compliance with Erp(EU) 2019/2020 |
|
Efficiency at 100% load
96.3% At 220Vac, 25°C, 500V/1.2A @ Pout=1200W
97% At 480Vac, 25°C, 500V/1.2A @ Pout=1200W |
|
Inrush Current
8A At 220Vac,50%Apk to 50%Apk time: 2ms
14A At 480Vac,50%Apk to 50%Apk time: 2ms |
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 At 220Vac, 25°C, 1200W output
0.98 At 480Vac, 25°C, 1200W output |
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
7.5% At 220Vac/50Hz, 25°C, 1200W output
12.5% At 480Vac/60Hz, 25°C, @ Pout=1200W |
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminum case, Dark Gray, compliance with C5 environment (ISO 9223)
|
|
|
Indicator
-
|
|
|
Cooling System
Natural Convection
|
|
|
Input Terminal
With the sign of L1, L2, PE
|
|
|
Output Terminal
With the sign of PE, NTC, V2+, V2-, V1+, V1-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
5.4 kg (11.90 lb)
|
Dimensions
500 x 152 x
77 mm
19.69” x 5.98” x 3.03” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40 ~+50°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10% to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
|
Storage Humidity
10% to 90% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
-
|
|
Overload / Overcurrent
-
|
|
Over Temperature
-
|
|
Short Circuit
-
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP66
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
475khrs. at Ta=+45°C Telcordia SR-332
|
|
Expected Cap Life Time
50,000 hours applicable for 220Vac to 480Vac(50/60Hz) @100% of load, @ Ta 45°C
|
|
Safety Certificate
ENEC:
EN 61347-2-13:2014, EN 61347-2-13/A1:2017 EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN IEC 62384:2020 CB report: EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN 61347-2-13:2014, EN 61347-2-13/A1:2017 UL: UL Compliant ANSI / UL8750 2nd Ed., CSA C22.2 No.250.13, 4th Ed. RCM: AS 61347-2-13: 2018 AS/NZS 61347-1: 2016+A1 CCC: GB 19510.1 GB 19510.14 |
|
Electrical Safety
-
|
|
CE
CE Declaration of Conformity.
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
BS EN 61347-2-13: 2014+A1:2017
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Radiated Emission EN55015
GB/T17743, FCC Part 15 Subpart B |
|
Immunity
-
|
|
Harmonic Current Emissions
IEC 61000-3-2, GB 17625.1
|
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
|
ESD Immunity
EN 61000-4-2
|
|
Radiated Immunity
-
|
|
EFT
EN 61000-4-4
|
|
Surge
(AC Mains)
EN 61000-4-5 - Common Mode: 10kV4 (Line to Earth, Neutral to Earth) - Differential Mode: 10kV4 (Line to Neutral) |
|
Conducted Immunity
-
|
|
Magnetic Field
EN 61000-4-3
|
|
Voltage Dips
EN 61000-4-11
|
|
Component Power Supply for General Use
-
|
150-550V
1650W
2A
187-528 Vac
150-550V
1800W
2A
187-528 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.