Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
200W
8.33A
85-264Vac
190 x 97 x 38 mm
7.48” x 3.82” x 1.50”
0.61 kg (1.34 lb)
** Discontinued Product **
PMH-24V200WCBJ, PMH-24V200WCBU, PMH-24V200WCBV
** NRND **
PMH-24V200WCBA, PMH-24V200WCBL, PMH-24V200WCBH, PMH-24V200WCBS, PMH-24V200WCBT
Recommended Model: PMT-24V200W2BR
| Model | Description |
|---|---|
| PMH-24V200WCBL | Front face |
| PMH-24V200WCBH | Harness connector |
| PMH-24V200WCBS | Terminal block, output isolated to PE |
| PMH-24V200WCBT | Harness connector, output isolated to PE |
** Discontinued Product **
PMH-24V200WCBJ, PMH-24V200WCBU, PMH-24V200WCBV
** NRND **
PMH-24V200WCBA, PMH-24V200WCBL, PMH-24V200WCBH, PMH-24V200WCBS, PMH-24V200WCBT
Recommended Model: PMT-24V200W2BR
24V
200W
8.33A
85-264Vac
190 x 97 x 38 mm
7.48” x 3.82” x 1.50”
0.61 kg (1.34 lb)
| Model | Description |
|---|---|
| PMH-24V200WCBL | Front face |
| PMH-24V200WCBH | Harness connector |
| PMH-24V200WCBS | Terminal block, output isolated to PE |
| PMH-24V200WCBT | Harness connector, output isolated to PE |
|
Output Current
8.33A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
22-28Vdc
|
|
Output Power
200W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5% (@ 85-264Vac input, 100% load)
|
|
Load Regulation
< 0.5% (@ 85-264Vac input, 0-100% load)
|
|
PARD
< 100mVpp @ -20°C to 70°C
< 240mVpp @ < -20°C to -30°C |
|
Start-up Time
< 1200ms @ 100Vac (100% load)
< 800ms @ 240Vac (100% load) |
|
Hold-up Time
> 20ms @ 115Vac & 230Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 0-100% load
(Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 100Hz) |
|
Start-up with Capacitive Loads
8,000μF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
120-375Vdc
|
|
Input Current
< 2.20A @ 115Vac, < 1.2A @ 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 89.5% @ 115Vac, > 91.5% @ 230Vac
|
|
Inrush Current
-
|
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.98 @ 115Vac, > 0.92 @ 230Vac
|
|
Leakage Current
< 0.75mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
0% load:2.3W typ. @ 115Vac & 230Vac
100% load:23W typ. @ 115Vac & 19W typ. @ 230Vac |
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.61 kg (1.34 lb)
|
Dimensions
190 x 97 x
38 mm
7.48” x 3.82” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-30°C to +70°C
|
|
Storage Temperature
-30°C to +85°C
|
|
Power De-rating
-20°C to -30°C de-rate power by 2.0% / °C
> 45°C de-rate power by 2% / °C |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,1 times per direction, 2 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); displacement of 0.35mm; 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
-
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
28.8-35.2V range, Hiccup Mode,
Non-Latching (Auto-Recovery) |
|
Overload / Overcurrent
> 120% of rated load current, Hiccup Mode, Non-Latching (Auto recovery)
|
|
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-recovery)
|
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with PE connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C |
|
Expected Cap Life Time
-
|
|
Safety Certificate
-
|
|
Electrical Safety
SIQ Bauart: EN 62368-1, EN 60335-1, EN 61558-1, EN 61558-2-16
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output : 4.5KVac
Input to Ground : 1.5KVac Output to Ground : Output non-isolated to PE (common pins connect to PE) (PMH-24V200WCBA, PMH-24V200WCBJ, PMH-24V200WCBL, PMH-24V200WCBH) 1.5KVdc (Output isolated to PE) (PMH-24V200WCBS, PMH-24V200WCBU, PMH-24V200WCBV, PMH-24V200WCBT) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
Output non-isolated to PE: PELV (EN 60335), SELV (EN 60950)
Output isolated to PE: SELV (EN 60335), SELV (EN 60950) |
|
Maritime
-
|
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
K 60950-1
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032, FCC Title 47: Class B, EN 55014-1, EN 61000-6-3
|
|
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-1, EN 55014-2
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
1500W
62.5A
90-264 Vac
36V
1000W
28A
90-264 Vac
48V
1500W
31.25A
90-264 Vac
24V
1200W
0-50A
85-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.