Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
48V
1500W
31.25A
90-264 Vac
204 x 127 x 40.5 mm
8.03” x 5.00” x 1.59”
1.5 kg (3.31 lb)
48V
1500W
31.25A
90-264 Vac
204 x 127 x 40.5 mm
8.03” x 5.00” x 1.59”
1.5 kg (3.31 lb)
|
Output Current
31.25A
|
|
Output Voltage
48V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
48-56 Vdc
|
|
Output Power
1500W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5%
|
|
Load Regulation
± 1%
|
|
PARD
<1% Vrated pk-pk @ rated load
|
|
Start-up Time
1000 ms @ 115 Vac, 500 ms @ 230 Vac
|
|
Hold-up Time
16 ms @ 1200 W load, 115 Vac
12 ms @ 1500 W load, 230 Vac |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ with 5-100% load change
|
|
Start-up with Capacitive Loads
6,000 µF
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
<50 ms
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
2,200 W peak for 3 sec, @ 180~264 Vac
|
|
Nominal Input Voltage
100-240 Vac
|
|
Input Voltage Range
90-264 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
15 A max.
|
|
Input Power (Standby Mode)
1.5 W typ. @ 230 Vac
|
|
Efficiency at 100% load
92.0% typ. @ 230 Vac
|
|
Inrush Current
40 A @ 264 Vac, cold/hot start
|
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 @ 115 V/50 Hz, 0.98 @ 230 V/50 Hz
|
|
Leakage Current
< 0.5 mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
SGCC / SGCC
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Force Cooling
|
|
|
Input Terminal
M 4.0 x 3 Pins, CN1 / AC Input
|
|
|
Output Terminal
M 3.5 x 4 Pins, CN101 / DC Output
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
10~12 AWG*5 (2X)
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
1.5 kg (3.31 lb)
|
Dimensions
204 x 127 x
40.5 mm
8.03” x 5.00” x 1.59” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 5 Hz to 500 Hz @ 2G; 15 min for X, Y, Z direction
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-20°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Temperature: > 50°C de-rate power by 2% / °C
Input: 1,500W @ 180-264Vac; 1,200W @ 180-100Vac; 1,200W de-rate power by 1.33%/Vac @ 90-100Vac; 1,000W @ 90Vac |
|
Operating Humidity
20 to 90% (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
< 45dB @ 80% load @ 25°C (Tolerance: ±2dB)
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
Main output 145% of rated normal voltage, Latch Mode
|
|
Overload / Overcurrent
Main output 130% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Standby 3.2A max with Hiccup Mode (Auto-Recovery)
|
|
Over Temperature
Latch Mode for Main output
|
|
Short Circuit
Hiccup Mode to Main output / Standby
(Auto-Recovery when the fault is removed) |
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Protection Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
T10 A / 250 V
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
500K hrs based on Telcordia SR-332 (@ 115 Vac, 1200W, 35°C)
|
|
Expected Cap Life Time
26,280 hrs, (@115 Vac, 1000W @ 25°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart: EN 62368-1, EN 60335-1 & IEC 61558-1/ -2-16
UL/cUL: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1, IEC 60335-1 & IEC 61558-1/ -2-16 CCC: GB 17625.1 BIS: IS 13252 (Part 1) |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 4.0 KVac
Input to Ground: 1.5 KVac Output to Ground: 1.5 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
EN 55035, KS C 9835
|
|
Immunity
EN/BS EN 55035, KS C 9835, & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6- 1 , EN/BS EN 61000-6-2
|
|
Harmonic Current Emissions
IEC/EN 61000-3-2, Meet Class A limit
|
|
Voltage Fluctuation and Flicker
EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
48V
320W
6.7A
90-264 Vac
48V
240W
5A
90-264 Vac
48V
150W
3.3A
90-264 Vac
48V
600W
12.5A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.