Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
600W
25A
90-264 Vac
225 x 124 x 41 mm
8.86” x 4.88” x 1.61”
1.2 kg (2.65 lb)
24V
600W
25A
90-264 Vac
225 x 124 x 41 mm
8.86” x 4.88” x 1.61”
1.2 kg (2.65 lb)
|
Output Current
25A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
21.6-26.4 Vdc
|
|
Output Power
600W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5% typ. @ 115 Vac & 230 Vac
|
|
Load Regulation
±0.5% typ.
|
|
PARD
< 150 mVpp @ 0°C to 70°C
450 mVpp typ. @ -30°C to 0°C |
|
Start-up Time
500 ms typ. @ 115 Vac & 230 Vac
|
|
Hold-up Time
18 ms typ. @ 115 Vac & 230 Vac
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 & 230 Vac input, 10-100% load
(Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz) |
|
Start-up with Capacitive Loads
8,000 µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
600.0 W
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
30 ms typ. @ 115 Vac & 230 Vac
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240 Vac
|
|
Input Voltage Range
90-264 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
127-375 Vdc
|
|
Input Current
6.0 A typ. @ 115 Vac
3.0 A typ. @ 230 Vac |
|
Input Power (Standby Mode)
1.5 W typ. @ 230 Vac
|
|
Efficiency at 100% load
91.0% typ. @ 230 Vac
|
|
Inrush Current
45 A typ. @ 230 Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.96 @ 115 Vac & 230 Vac
|
|
Leakage Current
< 0.8 mA @ 240 Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
SGCC / SGCC
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Force Cooling
|
|
|
Input Terminal
M3.5 x 9 Pins (Rated 300 V / 20 A)
|
|
|
Output Terminal
M3.5 x 9 Pins (Rated 300 V / 20 A)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
AWG 14-10
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
1.2 kg (2.65 lb)
|
Dimensions
225 x 124 x
41 mm
8.86” x 4.88” x 1.61” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2G ; 10 min per cycle, 60 min for each axis (X,Y,Z)
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2% / °C
< 100Vac de-rate power by 1% / V (90% load @ 90 Vac) |
|
Operating Humidity
20 to 90% (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
|
|
Pollution Degree
3
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
26.4 V - 33.6 V
SELV Output Latch Mode |
|
Overload / Overcurrent
105 - 150% of rated load current, Auto-recovery
Continuous current limit Mode (Vo > 80%) |
|
Over Temperature
Auto-recovery
|
|
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Protection Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
T10 A / 250 V
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs as per Telcordia SR-332
I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
|
Expected Cap Life Time
10 years (230 Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart: EN 62368-1, EN 60335-1
UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1, IEC 60335-1, IEC/EN 61558-1/-2-16 EAC: TP TC 004/2011 BSMI: CNS 15598-1 CCC: GB4943.1-2022 BIS: IS 13252 (Part 1) |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 4.0 KVac
Input to Ground: 2.0 KVac Output to Ground: 1.25 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, KS C 9832, AS/NZS CISPR32 & Compliance to FCC Title 47, EN/BS EN 55014-1 , EN/BS 61000-6-3 , EN/BS EN 61000-6-4 : Class B |
|
Immunity
EN/BS EN 55035, KS C 9835, & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6- 1 , EN/BS EN 61000-6-2
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A & Class D
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
600W
25A
80-275Vac
24V
600W
25A
85-264Vac
24V
320W
13.4A
90-264 Vac
24V
240W
10A
90-264 Vac
24V
150W
6.5A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.