Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
600W
25A
80-275Vac
203.1 x 101.6 x 40.6 mm
8.00” x 4.00” x 1.60”
1.1 kg (2.43 lb)
| Model | Description |
|---|---|
| IMA-S600-24-ZYPLI | Standard version, remote ON/OFF setting OFF, parallel operation |
| IMA-S600-24-ZYPLY | Standard version, remote ON/OFF setting ON, parallel operation |
| IMA-S600-24-ZYSLI | Standard version, remote ON/OFF setting OFF, single operation |
24V
600W
25A
80-275Vac
203.1 x 101.6 x 40.6 mm
8.00” x 4.00” x 1.60”
1.1 kg (2.43 lb)
| Model | Description |
|---|---|
| IMA-S600-24-ZYPLI | Standard version, remote ON/OFF setting OFF, parallel operation |
| IMA-S600-24-ZYPLY | Standard version, remote ON/OFF setting ON, parallel operation |
| IMA-S600-24-ZYSLI | Standard version, remote ON/OFF setting OFF, single operation |
|
Output Current
25A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
19.2-28.8V
|
|
Output Power
600W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
< 1% peak to peak
|
|
Start-up Time
< 2.5 s (@ AC OFF to ON, max. load)
< 150 ms (@ REMOTE OFF to ON, max. load) |
|
Hold-up Time
20 msec nominal
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
< 5%
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
80-275Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
120-300Vdc
|
|
Input Current
9A @ 80Vac
5.7A @ 120Vdc |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
92% @ 115Vac
94% @ 230Vac |
|
Inrush Current
< 20A
|
|
Charging Time
-
|
|
Power Factor at 100% load
0.9 (typical)
|
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
-
|
|
|
Indicator
-
|
|
|
Cooling System
Fan with variable speed control
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
1.1 kg (2.43 lb)
|
Dimensions
203.1 x 101.6 x
40.6 mm
8.00” x 4.00” x 1.60” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-20°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
When AC input voltage is < 90 Vac, the output power will be reduced by 6 W per 1 V.
|
|
Operating Humidity
< 95% (non-condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27 compliant, 50 g, 11 msec, 3 shocks for each direction
|
|
Vibration (Non-Operating)
IEC 60068-2-6 compliant, 2.09 Grms, 5 Hz to 500 Hz, 20 minutes per side (3 planes)
|
|
Storage Humidity
-
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
YES, latch mode
30V to 35V |
|
Overload / Overcurrent
YES, at 108% to 140% of nominal output current; auto recovery
|
|
Over Temperature
YES, auto recovery
|
|
Short Circuit
YES, auto recovery
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
500,000 hours (Telecordia SR-332, Issue 3, 25 °C, 90% confidence level)
|
|
Expected Cap Life Time
-
|
|
Case Temperature Rise
-
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 62368-1 (2014) Edition 2
UL 60950-1/CSA 22.2 No 60950-1, Edition 2 |
|
CE
-
|
|
Medical Safety
IEC 60601-1(2005), EN60601-1(2006)
ANSI/AAMI ES 60601-1(2005) CAN/CSA C22.2 No. 60601-1 (2008) |
|
Galvanic Isolation
Input to Output (Reinforced): 4000 Vac; 2 x MOPP
Input to Case (Basic): 1500 Vac; 1 x MOPP Output to Case (Basic): 1500 Vac; 1 x MOPP |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
48V
350.4W
7.3A
180-264 Vac
48V
750W
0-15.63A
85-264 Vac
24V
750W
0-31.25A
85-264 Vac
48V
76.8W
1.6A
180-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.