Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
15V
65W
4.33A
90-264Vac
115 x 50 x 29 mm
4.53” x 1.97” x 1.14”
0.25 kg (0.55 lb)
15V
65W
4.33A
90-264Vac
115 x 50 x 29 mm
4.53” x 1.97” x 1.14”
0.25 kg (0.55 lb)
|
Output Current
4.33A
|
|
Output Voltage
15V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
65W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5%
|
|
Load Regulation
± 4.5%
|
|
PARD
1%
|
|
Start-up Time
< 3000ms @ 115Vac & 230Vac
|
|
Hold-up Time
10ms typ. @ 115Vac
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 0-50% & 50-100% load; Slew rate 0.25A/µs (@ 100Hz, 50% Duty Cycle)
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 50ms @ 115Vac & 230Vac
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
90-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
1.5A @ 115Vac, 0.75A @ 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
-
|
|
Inrush Current
50A @ 115Vac and 100A @ 230Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
0.2mA @ 264Vac NC2), 0.5mA @ 264Vac SFC3)
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
PC
|
|
|
Indicator
Green LED
|
|
|
Cooling System
-
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.25 kg (0.55 lb)
|
Dimensions
115 x 50 x
29 mm
4.53” x 1.97” x 1.14” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +60°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
> 40°C de-rate power by 2.5% / °C
|
|
Operating Humidity
10-95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
5-500Hz, 2.09Grms, 20 minute for each three axis
|
|
Storage Humidity
-
|
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
150% max, Latch Mode
|
|
Overload / Overcurrent
(max.)
180% max of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery) |
|
Over Temperature
Latch Mode
|
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP22
|
|
Protection Against Shock
Class I
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
1 million Hours based on Telecordia SR-332 (at 115Vac, Max. load and 25°C Ambient)
|
|
Expected Cap Life Time
-
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 62368-1
IEC 60950-1 PSE J 62368-1 GB 4943.1-2022, GB/T 9254.1-2021, GB 17625.1-2012 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
|
|
Medical Safety
IEC 60601-1 CB report
EN 60601-1 CAN/CSA-C22.2 No. 60601-1 ANSI/AAMI ES60601-1 UL60601-1 |
|
Galvanic Isolation
Input to Output: 4000Vac
Input to PE: 1500Vac Output to PE: 500Vac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002)
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
IEC 62368-1
IEC 60950-1 PSE J 62368-1 GB 4943.1, GB/T 9254.1, GB 17625.1 |
|
SIL3
-
|
|
Emission
EN/BS EN 55011 Class B Compliance to EN/BS EN 55032, FCC Title 47: Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC61000-3-2
|
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
5V,9V,15V,20V
65W
3A,3A,3A,3.25A
90-264 Vac
5V,9V,15V,20V
45W
3A,3A,3A,2.25A
90-264 Vac
5V,9V,15V,20V
65W
3A,3A,3A,3.25A
90-264 Vac
5V,9V,12V,15V,20V
30W
3A,3A,2.5A,2A,1.5A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.