Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
2-60V
3000W
90-264Vac
254 x 181 x 40.5 mm
10.00” x 7.13” x 1.59”
2.5 kg (5.51 lb)
2-60V
3000W
90-264Vac
254 x 181 x 40.5 mm
10.00” x 7.13” x 1.59”
2.5 kg (5.51 lb)
|
Output Current
|
|
Output Voltage
2-60V
|
|
Output Voltage Range
test
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
3000W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
±0.5%
|
|
Load Regulation
±1%
|
|
PARD
-
|
|
Start-up Time
3000ms @ 115Vac
|
|
Hold-up Time
12ms @ rated load, with nominal input range
20ms @ 1500W load, with nominal input range Half rated load @200Vac/240Vac for SEMI F47 |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
±5% @ with 50-100% load change
±6% @ with 50-100% load change for H2/I2/J2 |
|
Start-up with Capacitive Loads
Single Slot Single Output Module:1500uF on each load
Triple Slot Single Output Module:2800uF on each load Single Slot Dual Output Module:1000uF on each load |
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
1% pk-pk Vrated or 100mV, which is greater
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
100ms
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
90-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
20A
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
90% @ 115Vac/60Hz
93% @ 230Vac/50Hz |
|
Inrush Current
40A @ 230Vac, cold start
|
|
Charging Time
-
|
|
Power Factor at 100% load
>0.95 @ 115V/50Hz, 230V/50Hz, full load
|
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
SGCC
|
|
|
Indicator
-
|
|
|
Cooling System
-
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
2.5 kg (5.51 lb)
|
Dimensions
254 x 181 x
40.5 mm
10.00” x 7.13” x 1.59” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-20°C to +70°C.
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
5-90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
5-500Hz, 2Grms, 20 minute for each three axis
|
|
Storage Humidity
-
|
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Overvoltage
Latch off. Reset by recycling AC or through I2C Programmable in 110% to 130% rated output voltage range through I2C.
|
|
Overload / Overcurrent
Hiccup Mode (Non-Latching, Auto-Recovery) Programmable in 110% to 130% rated output current range through I2C.
|
|
Over Temperature
Latch off
|
|
Short Circuit
Hiccup Mode (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 62368-1 CB report
UL 62368-1 CAN/CSA 62368-1 TUV 62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
|
Medical Safety
IEC 60601-1 2nd edition
IEC 60601-1 3rd edition + A1 CB report CSA 60601-1 ANSI/AAMI 60601-1 TUV 60601-1 |
|
Galvanic Isolation
Input to Output (2xMOPP): 4000Vac
Input to Ground (1xMOPP): 1500Vac Output to Ground: 500Vac (Type B application rated) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016, and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002)
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
EN/BS EN 55011, EN/BS EN 55032, FCC Title 47:Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC61000-3-2 Meet Class A limit
|
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.