Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
960W
40A
85-277 Vac
123.6 x 130.8 x 137 mm
4.87” x 5.15” x 5.39”
(0.00 lb)
| Model | Description |
|---|---|
| DRL-24V960W1ENA | Conformal Coating |
24V
960W
40A
85-277 Vac
123.6 x 130.8 x 137 mm
4.87” x 5.15” x 5.39”
(0.00 lb)
| Model | Description |
|---|---|
| DRL-24V960W1ENA | Conformal Coating |
|
Output Current
40A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
24-28 Vdc
|
|
Output Power
960W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5% @ 115 Vac & 230 Vac
|
|
Load Regulation
± 0.5%
|
|
PARD
< 150 mVpp @ 0°C to +70°C
< 450 mVpp @ -30°C to 0°C |
|
Start-up Time
300 ms typ. @ 230 Vac
|
|
Hold-up Time
22 ms typ. @ 230 Vac
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz)
|
|
Start-up with Capacitive Loads
10,000 µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
30 ms typ. @ 230 Vac
|
|
Power Boost Duration
150% Power Boost for 5 seconds / 200% for 50ms / 500% for 5ms
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240 Vac
|
|
Input Voltage Range
85-277 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
100-400 Vdc
|
|
Input Current
9.3 A typ. @ 115 Vac, 4.6 A typ. @ 230 Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
95% typ. @ 230 Vac
|
|
Inrush Current
30 A typ. @ 230 Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.98 @ 115 Vac, > 0.96 @ 230 Vac
|
|
Leakage Current
1.5 mA typ. @ 230 Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
4 W typ. @ 230 Vac
|
|
Case Chassis / Cover
Case Cover: Aluminum alloy, Chassis: Anodized aluminum, Front Cover: Galvanized steel
|
|
|
Indicator
Green LED DC OK
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
3 Pins (Rated 600 V / 30 A)
|
|
|
Output Terminal
4 Pins (Rated 600 V / 30 A)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
Sound Pressure Level (SPL) < 25 dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
Input: AWG 14-12
Output: AWG 12-10 |
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
(0.00 lb)
|
Dimensions
123.6 x 130.8 x
137 mm
4.87” x 5.15” x 5.39” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz (2G peak); 10 min per cycle, 60 min for X, Y, Z direction
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C @ 230 Vac
> 40°C de-rate power by 1.66% / °C @ 115 Vac |
|
Operating Humidity
5 to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction, 9 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-64, Random: 5 Hz to 500 Hz (2.09 G); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II (Compliance to EN 61558-1 OVC III with 2000 meters altitude)
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
<37 V, SELV Output, Hiccup Mode, Auto-recovery
|
|
Overload / Overcurrent
125 - 205% of rated load current, Hiccup Mode, Auto-recovery (150% Power Boost for 5 seconds / 200% for 50 ms / 500% for 5 ms)
|
|
Over Temperature
Shut down, Auto-recovery
|
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
Telcordia SR-332: > 700,000 hrs.
I/P: I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
|
Expected Cap Life Time
10 Years (115 Vac & 230 Vac, 50% load @ 45°C)
|
|
Case Temperature Rise
-
|
|
Safety Certificate
CB scheme: IEC/EN/BS EN 62368-1, AS/NZS 62368-1 RCM, IEC/EN 61010-1/2-201, IEC 61558-1/2-16, AS/NZS 61558-1/2-16 RCM
TUV Bauart: EN 62368-1 UL/cUL: UL 62368-1, CSA C22.2; UL 61010-1/-2-201, CAN/CSA-C22.2 No. 61010-1-12 BIS: IS 13252-1 (Part 1) BSMI: CNS 15598-1 CCC: GB 4943.1, EAC: TP TC 004/2011 KC: KC 62368-1 (upon request) |
|
Electrical Safety
-
|
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 4.0 kVac
Input to Ground: 2.5 kVac Output to Ground: 1.5 kVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV (IEC/EN 62368-1 /61010-1/2-201 /61558-1/2-16)
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, AS/NZS CISPR 32, Class B; KS C 9832; CNS15936; EN/BS EN 61204-3; Compliance to FCC Title 47 |
|
Immunity
EN/BS EN 55035; KS C 9835; EN/BS EN 61204-3
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3, dmax ≤ 4%
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
12V
120W
10A
85-277 Vac (305
24V
15W
0.63A
85-264 Vac
48V
960W
20A
3 x 340-575 Vac
48V
240W
5A
3 x 340-575 Vac