Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
48V
240W
5A
3 x 340-575 Vac (3-Phase) or 2 x 340-575 Vac (2-Phase)
123.6 x 56 x 116.8 mm
4.87” x 2.20” x 4.60”
0.70 kg (1.54 lb)
48V
240W
5A
3 x 340-575 Vac (3-Phase) or 2 x 340-575 Vac (2-Phase)
123.6 x 56 x 116.8 mm
4.87” x 2.20” x 4.60”
0.70 kg (1.54 lb)
|
Output Current
5A
|
|
Output Voltage
48V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
48-55 Vdc
|
|
Output Power
240W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5%
|
|
Load Regulation
± 1%
|
|
PARD
< 120 mVpp typ. @ 0°C to +70°C
< 300 mVpp typ. @ -30°C to 0°C |
|
Start-up Time
1500 ms typ. @ nominal input (100% load)
|
|
Hold-up Time
25 ms typ. @ 3 x 400 Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 3 x 340-575 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle@ 5 Hz & 10 kHz)
|
|
Start-up with Capacitive Loads
8,000 µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
50 ms typ. @ nominal input (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
3 x 380-500 Vac
|
|
Input Voltage Range
3 x 340-575 Vac (3-Phase) or 2 x 340-575 Vac (2-Phase)
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 0.85 A @ 3 x 400 Vac,
< 0.75 A @ 3 x 500 Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
89.0% typ. @ 3 x 400 Vac & 3 x 500 Vac
|
|
Inrush Current
50 A typ. @ 3 x 400 Vac & 3 x 500 Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.4 @ 3 x 400 Vac & 3 x 500 Vac
|
|
Leakage Current
< 1 mA @ 3 x 400 Vac & 3 x 500 Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED DC OK
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
4 Pins (Rated 600 V / 30 A)
|
|
|
Output Terminal
4 Pins (Rated 600 V / 30 A)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 25 dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
|
Wire
Input: AWG 18-10
Output: AWG 16-10 |
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.70 kg (1.54 lb)
|
Dimensions
123.6 x 56 x
116.8 mm
4.87” x 2.20” x 4.60” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 19.6 m/s² (2 G peak); 10 min per cycle, 60 min for X, Y, Z direction.
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5 % / °C
|
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction, 9 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09 G); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2,000 meters altitude)
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
< 68 V, SELV Output, Auto-recovery Mode
|
|
Overload / Overcurrent
105 – 180% of rated load current, Auto-recovery (150% Power Boost for 500 ms)
|
|
Over Temperature
Non-Latching (Auto-recovery)
|
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP20
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
Telcordia SR-332: > 700,000 hrs.
I/P: 3 x 400 Vac & 3 x 500 Vac, O/P: 100% load, Ta: 25°C |
|
Expected Cap Life Time
10 Years
I/P: 3 x 400 Vac & 3 x 500 Vac, O/P: 50% load, Ta: 40°C |
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart: IEC/EN 62368-1
UL/cUL: UL 62368-1, CSA C22.2; UL 61010-1/-2-201, CAN/CSA-C22.2 No. 61010-1-12 CB scheme: IEC/EN/BS EN 62368-1, AS/NZS 62368-1; IEC/EN 61010-1/-2-201 CCC: GB4943.1 BIS: IS 13252-1 (Part 1) BSMI: CNS15598-1 EAC: TP TC 004/2011 KC: KC 62368-1 (upon request) |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 4.0 kVac
Input to Ground: 2.5 kVac Output to Ground: 0.5 kVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV (IEC/EN 61010-1/2-201, IEC/EN 62368-1)
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
(CE & RE)
Generic Standards: CISPR 32, EN/BS EN 55032, AS/NZS CISPR 32 ,Class B; KS C 9832; CNS15936; EN/EN BS 61000-6-4, EN/BS EN 61204-3; Compliance to FCC Title 47 |
|
Immunity
Generic Standards: EN/BS EN 55035; KS C 9835; EN/BS EN 61000-6-2 ; EN/BS EN 61204-3
|
|
Harmonic Current Emissions
IEC/EN/EN BS 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/EN BS 61000-3-3, dmax ≤ 4%
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
48V
960W
20A
85-277 Vac (305
48V
240W
5A
85-277 Vac (305
24V
480W
20A
85-277 Vac (305
48V
120W
2.5A
3 x 340-575 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.