Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
120W
5A
85-264Vac
121 x 50 x 123.1 mm
4.76” x 1.97” x 4.85”
0.72 kg (1.59 lb)
| Model | Description |
|---|---|
| DRP024V120W1BN | Without Class I, Div 2 and ATEX |
24V
120W
5A
85-264Vac
121 x 50 x 123.1 mm
4.76” x 1.97” x 4.85”
0.72 kg (1.59 lb)
| Model | Description |
|---|---|
| DRP024V120W1BN | Without Class I, Div 2 and ATEX |
|
Output Current
5A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
24-28Vdc
|
|
Output Power
120W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5% (@ 85-264Vac input, 100% load)
|
|
Load Regulation
< 1.0% (@ 85-264Vac input, 0-100% load)
|
|
PARD
< 150mVpp
|
|
Start-up Time
< 1000ms @ nominal input (100% load)
|
|
Hold-up Time
> 20ms @ 115Vac,
> 115ms @ 230Vac (100% load) |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 10-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
|
Start-up with Capacitive Loads
10,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 50ms @ nominal input (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
120-375Vdc
|
|
Input Current
< 2.20A @ 115Vac,
< 1.10A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 89.0% @ 115Vac,
> 90.0% @ 230Vac |
|
Inrush Current
< 35A @ 115Vac & 230Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 1mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
0% load: < 0.3W @ 115Vac & < 0.5W @ 230Vac
100% load: < 7.0W @ 115Vac & 230Vac |
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
3 Pins (Rated 300V/15A)
|
|
|
Output Terminal
4 Pins (Rated 300V/15A)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 40dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
|
Wire
Input / Output: AWG 20-14
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.72 kg (1.59 lb)
|
Dimensions
121 x 50 x
123.1 mm
4.76” x 1.97” x 4.85” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-25°C to +80°C (Cold Start at -40°C)
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Vertical / Horizontal: > 50°C de-rate power by 2.5% / °C
|
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 time per direction, 2 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 2,000 Meters (6,560 ft)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
III
According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
|
Corrosion
-
|
|
Overvoltage
< 32V ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
|
|
Overload / Overcurrent
> 150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP20
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 800,000 hrs. as per Telcordia SR-332 (I/P: 115Vac, O/P: 100% load, Ta: 25°C)
|
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
SIQ Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
For DRP024V120W1BA: In conformance with Equipment for explosive atmospheres (ATEX) directive 2014/34/EU |
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 4.0KVac
Input to Ground: 1.5KVac Output to Ground: 1.5KVac |
|
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
CSA: CSA C22.2 No. 107.1-01 (File No. 181564) |
|
Hazardous Location / ATEX
(For DRP024V120W1BA)
cCSAus: CSA C22.2 No. 213-M1987, ANSI / ISA 12.12.01:2011 [Class I, Division 2, Group A, B, C, D T4, Ta= -25°C to +80°C (> +50°C derating)] ATEX: EN 60079-0:2009, EN 60079-15:2010 [II 3G Ex nA nC IIC T4 Gc, Ta= -25°C to +80°C (> +50°C derating)] Certificate No. EPS 12 ATEX 1 491 X |
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
EN 60204-1 (over voltage category III)
|
|
Electrical Equipment for Use in Electrical Power Installations
IEC/EN 62477-1 / IEC 62103
|
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with 2016 No. 1101. The Electrical Equipment (Safety) Regulations 2016 and 2016 No. 1091 The Electromagnetic Compatibility Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
(CE & RE)
Generic Standards: CISPR 32, EN 55032, KN 32 (for DRP024V120W1BN), CISPR 11, EN 55011, FCC Title 47: Class B |
|
Immunity
Generic Standards: EN 55024, KN 35 (for DRP024V120W1BN), EN 61000-6-1, EN 61000-6-2
|
|
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
EN 61204-3
|
24V
480W
20A
3 x 340-575 Vac
48V
480W
10A
85-277 Vac (305
24V
960W
40A
3 x 340-575 Vac
48V
960W
20A
3 x 320-575 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.