48V
1500W
31.25A
90-264 Vac
204 x 127 x 40.5 mm
8.03” x 5.00” x 1.59”
1.5 kg (3.31 lb)
48V
1500W
31.25A
90-264 Vac
204 x 127 x 40.5 mm
8.03” x 5.00” x 1.59”
1.5 kg (3.31 lb)
|
Output Current
31.25A
|
|
Output Voltage
48V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
1500W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
1%
|
|
Load Regulation
2%
|
|
PARD
-
|
|
Start-up Time
1000 ms @ 115 Vac
500 ms @ 230 Vac |
|
Hold-up Time
16 ms @ 120 0W load, 115 Vac
12 ms @ 1500 W load, 230Vac |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ with 5-100% load change
|
|
Start-up with Capacitive Loads
6000uF
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
1% pk-pk Vrated@ rated load, @25°C
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
<50ms
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240 Vac
|
|
Input Voltage Range
90-264 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
15A
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
(typ.)
89% @ 115 Vac 92% @ 230 Vac |
|
Inrush Current
40 A @ 264 Vac, cold start
|
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 @ 115 V/60 Hz, full load
0.98 @ 230 V/50 Hz, full load |
|
Leakage Current
Earth Leakage Current (Input to PE): 0.5 mA @ NC, 1.0 mA @ SFC
0.15 mA @ NC, 0.30 mA @ SFC Touch Current (Output to PE): 0.1 mA @ NC, 0.5 mA 0.1 mA @ NC, 0.2 mA |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
-
|
|
|
Indicator
Green LED
|
|
|
Cooling System
-
|
|
|
Input Terminal
M4.0 x 3 Pins (Rated 300V/25A)
|
|
|
Output Terminal
M3.5 x 4 Pins (Rated 300V/32A)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
8 AWG * (2X)
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
1.5 kg (3.31 lb)
|
Dimensions
204 x 127 x
40.5 mm
8.03” x 5.00” x 1.59” |
|
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
Absolute Maximum/Minimum Rating. -20°C to +70°C. Linear power derate from 100% load at 50°C, to 50% load at 70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
20-90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
Main output 145% of rated normal voltage, Latch Mode
|
|
Overload / Overcurrent
Main output 135% of rated current, constant current
Standby 4.0A max with Hiccup Mode (Non-Latching, Auto-Recovery) |
|
Over Temperature
Latch Mode for Main output
|
|
Short Circuit
Hiccup Mode for Main output and Standby (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
CB scheme: IEC62368-1 CB report
CB scheme: IEC60950-1 CB report TUV Bauart: EN/ BS EN 62368-1 UL/cUL: UL62368-1+CAN/CSA62368-1 CCC:GB4943.1-2022, GB9254-2021, GB17625.1-2012 CB scheme:IEC 60335-1 CB report, IEC 61558-1/ -2-16 CB report TUV Bauart: EN/ BS EN 60335-1, EN/ BS EN 61558-1 / -2-16 |
|
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
|
|
Medical Safety
CB scheme:IEC60601-1 3rd+A1+A2 edition CB report
TUV Bauart: EN/ BS EN 60601-1:2006 UL/cUL: ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1: (Ed.3.2005) |
|
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500 Vac Output to/Ground(1XMOPP): 1500 Vac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 (UK MDR 2002)
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
EN/ BS EN 55011, EN/ BS EN 55032 : Class B
EN/ BS EN 55014-1 (for MEB-1K5A24T AAA) CISPR 11, CISPR 32 : Class B KS C 9832 Compliance to FCC Title 47 Class B |
|
Immunity
BS EN / EN 55035, KS C 9835, EN/ BS EN 55014-2
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2 Meet Class A limit
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
200W
0-8.34A
90-264 Vac
24V
501.6W
0-20.9A
85-264 Vac
48V
2500W
52.1A
85-264 Vac
12V
500.4W
0-41.7A
85-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.