Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
504W
21A
90-264Vac
165.3 x 85.2 x 41 mm
6.51” x 3.35” x 1.61”
0.66 kg (1.46 lb)
| Model | Description |
|---|---|
| MEB-500A24F AA | Remote On/Off, conformal coating |
24V
504W
21A
90-264Vac
165.3 x 85.2 x 41 mm
6.51” x 3.35” x 1.61”
0.66 kg (1.46 lb)
| Model | Description |
|---|---|
| MEB-500A24F AA | Remote On/Off, conformal coating |
|
Output Current
21A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
21.6V~26.4V
|
|
Output Power
504W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
96mv max.
|
|
Load Regulation
150mv max.
|
|
PARD
< 300mVpp @ 0~+50°C
< 360mvVpp @-20~0°C. |
|
Start-up Time
800ms max.
|
|
Hold-up Time
16ms typ. @ 120Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
±10% @50-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 100Hz)
|
|
Start-up with Capacitive Loads
8,800μF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
90-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
5A typ.@ 120Vac , 2.6A typ. @ 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
92% typ. @ 230Vac
|
|
Inrush Current
40A typ. @ 230Vac, Cold start, @ 25°C
|
|
Charging Time
-
|
|
Power Factor at 100% load
0.98 typ. @ 115Vac, 0.96 typ. @ 230Vac
|
|
Leakage Current
输入对PE(保护地线)漏电流(最大值): 0.25 mA @ NC, 0.5 mA @ SFC
Type BF应用输出对PE(保护地线)漏电流(最大值): 0.1 mA @ NC, 0.3 mA @ SFC |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
Aluminum
|
|
|
Indicator
-
|
|
|
Cooling System
Built-in Fan
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
Sound Pressure Level (SPL) < 60dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
AWG 22-12
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.66 kg (1.46 lb)
|
Dimensions
165.3 x 85.2 x
41 mm
6.51” x 3.35” x 1.61” |
|
Vibration (Operating)
IEC60068-2-6, Sine Wave: 10Hz to 55Hz@19.6m/s2(2G peak); 10min per cycle, 60min per axis for all X,Y,Z direction
|
|
Shock Test (Operating)
IEC60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3shocks for each 3 directions
|
|
Operating Temperature
-20°C to +70°C
|
|
Storage Temperature
-30°C to +80°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
|
|
Operating Humidity
20 to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 3,000 Meters (9,840 ft.) - IEC 60601-1
0 to 5,000 Meters (16,400 ft.) - IEC 60950-1 & IEC 62368-1 |
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
115-140% (27.6 – 33.6V)
105-150% (5.25 – 7V) Protection mode: Latch OFF |
|
Overload / Overcurrent
>105% rated full load current, Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
|
Over Temperature
Protection mode: Latch OFF.
|
|
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with PE connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 Hrs. Based on Telecordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C |
|
Expected Cap Life Time
3 years (115Vac, 100% load @ 50°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 60950-1 & IEC 62368-1 CB report
TUV 60950-1 UL 60950-1 + CAN/CSA 60950-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
|
Medical Safety
IEC 60601-1 CB report
TUV EN 60601-1 UL 60601-1 + ANSI/AAMI ES60601-1 + CAN/CSA 60601-1 |
|
Galvanic Isolation
Input to Output (2XMOPP): 4.0KVac
Input to Earth (1XMOPP): 1.5KVac Output to Earth (1XMOPP): 1.5KVac (Type BF application rated) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
RoHS Directive 2011/65/EU & EU/2015/863 Compliant
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016
and Electromagnetic Compatibility Regulations 2016 Medical Devices Regulations 2002(UK MDR 2002) |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
EN/BS EN 55011 & compliant with EN/BS EN 55032, FCC Title 47:Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
Meet Class A limit
|
|
Voltage Fluctuation and Flicker
-
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
18V
500.4W
0-27.8A
85-264 Vac
12V
500.4W
0-41.7A
85-264 Vac
48V
504W
0-10.5A
85-264 Vac
12V
200W
0-16.67A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.