Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
48V
320W
6.7A
180-528Vac
262 x 90 x 43.8 mm
10.31” x 3.54” x 1.72”
1.19 Kg (2.62 lb)
Model | Description |
---|---|
LNV-48V320WBAA | IP67, dimming cable & potentiometers, UL approval |
LNV-48V320WDAA | IP67, dimming cable, UL approval |
48V
320W
6.7A
180-528Vac
262 x 90 x 43.8 mm
10.31” x 3.54” x 1.72”
1.19 Kg (2.62 lb)
Model | Description |
---|---|
LNV-48V320WBAA | IP67, dimming cable & potentiometers, UL approval |
LNV-48V320WDAA | IP67, dimming cable, UL approval |
Output Current
6.7A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
43.0-53.0V
|
Output Power
320W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% @180-528Vac
|
Load Regulation
± 0.5% @180-528Vac (0-95% load)
|
PARD
< 250mVpp
|
Start-up Time
< 500ms @ 230Vac
|
Hold-up Time
16ms typ. @ 230Vac & 277Vac & 480Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-90% load, @ 230Vac & 277Vac & 480Vac
(Slew Rate: 0.1A/µS,90% duty cycle @ 120Hz &1KHz) (For CV Operation Only) |
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
24-48Vdc
|
Rise Time
< 50ms @ 230Vac & 277Vac & 480Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
200-480Vac
|
Input Voltage Range
180-528Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.7A max. @ 230Vac, 1.4A max. @ 277Vac, 1.0A max. @ 480Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
92.0% typ. @ 230Vac, 93.0% typ. @ 277Vac, 93.5% typ. @ 480Vac
|
Inrush Current
(Cold Start)
50A typ. @ 480Vac |
Charging Time
-
|
Power Factor at 100% load
0.98 typ. @ 230Vac & 277Vac
0.95 typ. @ 480Vac |
Leakage Current
< 0.75mA @ 480Vac/60Hz
|
Nominal Current
-
|
Total Harmonic Distortion
< 20% @ 230Vac/60 Hz & 277Vac/60 Hz (≥ 50% load)
< 20% @ 347Vac/60 Hz & 480Vac/60 Hz (≥ 70% load) |
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
1.19 Kg (2.62 lb)
|
Dimensions
262 x 90 x
43.8 mm
10.31” x 3.54” x 1.72” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +60°C (Vin: 180Vac)
-40°C to +65°C (Vin: 230Vac) -40°C to +70°C (Vin: 270Vac and above) |
Storage Temperature
-40°C to +85°C
|
Power De-rating
Vin: 180Vac: > 50°C de-rate power by 4% / °C
Vin: 230Vac: > 55°C de-rate power by 4% / °C Vin: 277Vac: > 60°C de-rate power by 4% / °C |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G);
20 min per axis for all X, Y, Z direction |
Storage Humidity
-
|
Operating Altitude
0 to 3,000 Meters (9,840 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
55.2-67.2V, Latch Mode
|
Overload / Overcurrent
95-108% of rated load current, constant current limit, Auto-Recovery when the fault is removed
|
Over Temperature
Hiccup Mode, Auto-Recovery when the fault is removed
|
Short Circuit
Constant current limit, Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
IP65 (LNV-☐V320WAAA)
IP67 (LNV-☐V320WBAA and LNV-☐V320WDAA) |
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332 (I/P: 200Vac, O/P: 100% load, Ta: 25°C)
|
Expected Cap Life Time
7 years (Input @ 230Vac OR 347Vac, Output @ 100% load AND CASE TEMPERATURE (tc) ≤ 75°C)
AND 10 years (Input @ 230Vac, Output @ 50% load @ AMBIENT TEMPERATURE (Ta) = 40°C) |
Safety Certificate
-
|
Electrical Safety
cRUus to UL 8750
(Type H/L included in safety approval and dry, damp, wet ratings) |
CE
-
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.85kVac
Input to Ground: 2.0kVac Output to Ground: 1.5kVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
Compliance to FCC Title 47: Class B |
Immunity
Compliance to EN 61547 and EN 55024
|
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
|
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
60-200V
130W
0.2-1.05A
198-264Vac
150-550V
1800W
2A
187-528 Vac
200-550V
600W
2A
198-440Vac
24V
20W
0.833A
198-264Vac