24V
80A
10.8-60 Vdc
124.2 x 44 x 126.9 mm
4.89” x 1.73” x 5.00”
0.46 kg (1.01 lb)
24V
80A
10.8-60 Vdc
124.2 x 44 x 126.9 mm
4.89” x 1.73” x 5.00”
0.46 kg (1.01 lb)
|
Output Current
80A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
0.15 V typ.
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
12-56 Vdc
|
|
Input Voltage Range
10.8-60 Vdc
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
-
|
|
Input Frequency Range
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
12-30 V 80 A Max. / 30-60 V 40 A - 80 A Max.
(1+1 Redundancy) = Nom. 12 V / 24 V 2×40 A / 48 V 2×25 A (N+1 Redundancy) = Nom. 12 V / 24 V 2×40 A / 48 V 2×25 A (Single unit use) = Nom. 12 V / 24 V 80 A / 48 V 50 A Max. |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 99.0% typ.
|
|
Inrush Current
-
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
Standby Mode: < 1 W
Operating Mode: < 15 W |
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
Case Cover: Galvanized steel with organic coating (SGCC)
Chassis: Aluminum alloy with organic coating |
|
|
Indicator
Green LED (DC OK): Vin1 and Vin2
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
4 Pins (Rated 600 V / 65 A)
|
|
|
Output Terminal
2 Pins (Rated 600 V / 125 A)
|
|
|
Signal Terminal
4 Pins (Rated 300 V / 7A)
|
|
|
Noise Sound Pressure Level (SPL)
< 40 dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
|
Wire
Input: AWG 8
Output: AWG 4 DC OK: AWG 22 |
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.46 kg (1.01 lb)
|
Dimensions
124.2 x 44 x
126.9 mm
4.89” x 1.73” x 5.00” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz (2G peak); 10 min per cycle, 60 min for X, Y, Z direction
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to +80°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Vertical Mounting: > 70°C de-rate power by 3% / °C
Horizontal Mounting: > 70°C de-rate power by 3% / °C |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction, 9 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-64, Random: 5 Hz to 500 Hz (2.09 G); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5000 Meters (16,666 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
-
|
|
Overload / Overcurrent
12 V / 24 V: 80 A: < 160 A, No Damage
48 V: 50 A: < 100 A, No Damage |
|
Over Temperature
-
|
|
Short Circuit
12 V / 24 V: 80 A: < 160 A, No Damage
48 V: 50 A: < 100 A, No Damage |
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP20
|
|
Protection Against Shock
Class III with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
> 800,000 hrs. as per Telcordia SR-332
I/P: 24 Vdc and 48 Vdc, O/P: 100% load, Ta: 25°C |
|
Expected Cap Life Time
-
|
|
Case Temperature Rise
-
|
|
Safety Certificate
CB Scheme: IEC/EN 62368-1, AS/NZS 62368.1 RCM; IEC 61010-1/2-201
UL/cUL Recognized: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 (File No. E131881) TUV: EN/IEC 62368-1 UKCA: BS EN 62368-1 EAC: TP TC 020/2011 |
|
Electrical Safety
-
|
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to PE: 1.5 KVac
Output to PE: 1.5 KVac Input/Output to DC OK: 0.5 KVac |
|
Industrial Control Equipment
UL/cUL Listed: UL 61010-1/2-201 and CAN/CSA C22.2 No. 61010-1/2-201 (File No. E338991)
|
|
Hazardous Location / ATEX
ATEX (Zone 2): II 3 G Ex ec nC IIC Gc
EN IEC 60079-0:2018 EN IEC 60079-7:2015/A1:2018 EN IEC 60079-15:2019 |
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032 Class B AS/NZS CISPR 32 Class B / KS C 9832 |
|
Immunity
EN/BS EN 55035
KS C 9835 |
|
Harmonic Current Emissions
-
|
|
Voltage Fluctuation and Flicker
-
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.