Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
960W
40A
18-30 Vdc
124 x 50 x 117 mm
4.88” x 1.97” x 4.61”
0.66 kg (1.46 lb)
24V
960W
40A
18-30 Vdc
124 x 50 x 117 mm
4.88” x 1.97” x 4.61”
0.66 kg (1.46 lb)
Output Current
40A
|
Output Voltage
24V
|
Output Voltage Range
17.5-29.5Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
960W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
15 s, 30 s, 45 s, 1 min, 3 min, 5 min, 10 min, 20 min, 30 min, ∞
|
Line Regulation
-
|
Load Regulation
-
|
PARD
-
|
Start-up Time
-
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
Charging Mode: 0.5V between DC input to load
Buffering Mode: 0.5V between battery to load |
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
-
|
Power Boost Duration
7 seconds
|
Power Boost Recovery Time
5 seconds
|
Nominal Input Voltage
24 Vdc
|
Input Voltage Range
18-30 Vdc
|
Max Input Voltage
-
|
Nominal Input Frequency
-
|
Input Frequency Range
|
Nominal DC Input Voltage
|
DC Input Voltage Range
18-30 Vdc
|
Input Current
Charging Mode: 1 A, 2 A, 3 A, 4 A (typ.)
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
98% typ.
|
Inrush Current
-
|
Charging Time
< 4.5 hr ± 1 hr (4 A charging current for 24 V/12 AH battery)
|
Power Factor at 100% load
-
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium
|
|
Indicator
Green LED: Battery Status
Orage LED: Diagnosis Red LED: Error |
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 40 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input / Output: AWG 18-8 (Load: 0-5 A), AWG 14-8 (Load: 5-10 A)
Battery: AWG 18-8 (Load: 0-5 A), AWG 14-8 (Load: 5-10 A) Signal: AWG 24-12 |
|
Protection Structure
-
|
|
Terminal
Input / Output: 4 Pins
Battery: 2 Pins Signal: 8 Pins Temperature Sensor & Rx/Tx: 4 Pins (CVILUX CP3504P1H00-NH) |
|
Unit Weight
0.66 kg (1.46 lb)
|
Dimensions
124 x 50 x
117 mm
4.88” x 1.97” x 4.61” |
Vibration (Operating)
EN 60068-2-64 (Wind Power Application)
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 60°C de-rate power by 2.5% / °C (when battery is fully charged) If the battery is not fully charged at max load, it is recommended that the surrounding air temperature should not exceed 50°C.
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30 G (300 m/s²) for a duration of 18 ms, 1 time per direction, 2 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, 10 Hz to 500 Hz @ 30 m/s² (3 G peak); 60 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 6,000 m (Approvals apply only up to 5,000 m)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Auto Recovery
|
Overload / Overcurrent
Normal Operation: Auto Recovery
Battery Operation: Latch off |
Over Temperature
Normal Operation: Auto Recovery
Battery Operation: Latch off |
Short Circuit
Buffering Mode: Shutdown, Latch Mode
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
Class III
|
Input Polarity Protection
Yes
|
Battery Polarity Protection
Yes
|
Wrong Battery Voltage Protection
Yes, 30 Vdc Max (the maximum voltage that will not cause damage to the unit)
|
Deep Discharge Protection
Yes (21 V typ.)
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
Yes
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1
TUV Bauart: EN 62368-1 UL/cUL recognized: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 (File No. E131881) EAC: TP TC 002/2011 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Power Port to Housing: 500 Vac
Signal Port to Housing: 500 Vac Power Port to Signal Port: 500 Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
CE & RE
EN/BS EN 61000-6-4, EN 61204-3 |
Immunity
EN/BS EN 61000-6-2, EN 61204-3
|
Harmonic Current Emissions
-
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
EN 61204-3
|
Nominal Battery Voltage
24 Vdc, SLA Sealed lead acid battery
2 x 12 Vdc, SLA Sealed lead acid battery in series |
Battery Voltage Range
21-27.6Vdc (continuously operating)
30Vdc Max (the maximum voltage that will not cause damage to the unit) 19.2Vdc Min (the voltage level of battery tol enable “Repl. BAT.” relay contact. (DRU module will not charge the battery) |
Battery Capacity
3.4 AH ~ 100 AH
|
Battery Charging Mode
1 A, 2 A, 3 A, 4 A (typ.) (constant current)
|
End of Charge Voltage
27.6 V
|
Battery Fuse
2 pcs in parallel; LITTELFUSE: 0257030. PXAPC, BUSSMANN: ATC-30 or equivalent (for DRN-24V7AAEN)
|
Battery Discharging Voltage Range
21 Vdc ... 27.6 Vdc
30 Vdc Max (the maximum voltage that will not cause damage to the unit) |
Battery Charging Current
1 A, 2 A, 3 A, 4 A (typ.) (constant current)
|
Battery Current Consumption
< 200 mA
|
Discharging Current
-
|
Recommended Charging Voltage
-
|