Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V
100W
8.34A
85-264Vac
158 x 97 x 38 mm
6.22” x 3.82” x 1.50”
0.45 kg (0.99 lb)
** Discontinued Product **
PMC-12V100W1AA
Recommended Model: PMT-12V100W2BA / PMT-12V100W2BAC
** NRND **
PMC-12V100W1AH, PMC-12V100W1AL
Recommended Model: PMT-12V100W2BA
| Model | Description |
|---|---|
| PMC-12V100W1AL | Front face connector |
| PMC-12V100W1AH | Harness connector |
** Discontinued Product **
PMC-12V100W1AA
Recommended Model: PMT-12V100W2BA / PMT-12V100W2BAC
** NRND **
PMC-12V100W1AH, PMC-12V100W1AL
Recommended Model: PMT-12V100W2BA
12V
100W
8.34A
85-264Vac
158 x 97 x 38 mm
6.22” x 3.82” x 1.50”
0.45 kg (0.99 lb)
| Model | Description |
|---|---|
| PMC-12V100W1AL | Front face connector |
| PMC-12V100W1AH | Harness connector |
|
Output Current
8.34A
|
|
Output Voltage
12V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
11-14Vdc
|
|
Output Power
100W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5% (@ 85-264Vac input, 100% load)
|
|
Load Regulation
< 1.0% (@ 85-264Vac input, 0-100% load)
|
|
PARD
< 100mVpp
|
|
Start-up Time
< 1000ms @ nominal input (100% load)
|
|
Hold-up Time
> 15ms @ 115Vac,
> 80ms @ 230Vac (100% load) |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac, 0-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz) |
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 30ms @ nominal input (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
125-250Vdc
|
|
DC Input Voltage Range
125-375 Vdc
|
|
Input Current
< 2.0A @ 115Vac,
< 1.1A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 84% @ 115Vac,
> 86% @ 230Vac |
|
Inrush Current
< 60A @ 115Vac,
< 130A @ 230Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 1mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
0% load: < 1.5W @ 115Vac & 230Vac
100% load: < 18.5W @ 115Vac, < 15W @ 230Vac |
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 40dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.45 kg (0.99 lb)
|
Dimensions
158 x 97 x
38 mm
6.22” x 3.82” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% /°C
|
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 3 times per direction, 18 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 3,000 Meters (9,840 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
16V +10%/-5%, SELV output, Hiccup Mode, Non-Latching (Auto-Recovery)
|
|
Overload / Overcurrent
> 120% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
< 75°C Ambient Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP20 (PMC-12V100W1AJ)
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
(I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C) |
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load and 40°C)
|
|
Case Temperature Rise
-
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1 CCC: GB9254, GB17625.1 and GB4943.1 (仅适用于海拔 2000m 以下地区安全使用) |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
K60950-1
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032,
AS/NZS CISPR 32:2013 Class B, KN 32 FCC Title 47: Class B, GB9254 |
|
Immunity
Generic Standards: EN/BS EN 55024, KN 35
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
750W
0-31.25A
85-264 Vac
48V
1000W
21A
90-264 Vac
48V
1200W
0-25A
85-264 Vac
36V
1000W
28A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.