Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
48V
150W
3.125A
85-264Vac
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.53 kg (1.17 lb)
** NRND **
Recommended Model: PMR-48V150W1AT
** NRND **
Recommended Model: PMR-48V150W1AT
48V
150W
3.125A
85-264Vac
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.53 kg (1.17 lb)
|
Output Current
3.125A
|
|
Output Voltage
48V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
44-53Vdc
|
|
Output Power
150W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5% typ. (@ 85-264Vac, 100% load)
|
|
Load Regulation
< 1% typ. (@ 85-264Vac, 0-100% load)
|
|
PARD
< 200mVpp
|
|
Start-up Time
< 3,000ms @ nominal input (100% load)
|
|
Hold-up Time
> 30ms @ 115Vac & 230Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 0-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
|
Start-up with Capacitive Loads
2,000μF Max @ 25°C (CC and CR mode)
1,000μF Max @ -10°C and 50°C (CC mode) 2,000μF Max @ -10°C and 50°C (CR mode) |
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
125-250Vdc
|
|
DC Input Voltage Range
125-375Vdc
|
|
Input Current
< 1.70A @ 115Vac,
< 1.00A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 89.0% @ 115Vac,
> 91.0% @ 230Vac |
|
Inrush Current
< 20A @ 115Vac,
< 40A @ 230Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.99 @ 115Vac,
> 0.92 @ 230Vac |
|
Leakage Current
< 1.5mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED DC OK
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 40dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.53 kg (1.17 lb)
|
Dimensions
178 x 97 x
38 mm
7.01” x 3.82” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
|
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 time per direction, 2 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
ll
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
< 63V, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Overload / Overcurrent
> 120% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C |
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
SIQ Bauart: EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1 CCC: GB4943 UKCA: BS EN 62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032, FCC Title 47: Class B, GB9254
|
|
Immunity
Generic Standard: EN/BS EN 55024
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
750W
0-31.25A
85-264 Vac
48V
600W
12.5A
90-132Vac, 180-
24V
2500W
0-104.2A
85-264 Vac
12V
720W
60A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.