Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V
50W
4.17A
90-264Vac
98 x 98 x 38 mm
3.86” x 3.86” x 1.50”
0.23 kg (0.51 lb)
** EOL **
PMT-12V50W1AG, PMT-12V50W1AH, PMT-12V50W1AAB
** NRND (Not Recommended for New Designs) **
PMT-12V50W1AA (Last Buy Date: 2026/7/31~2027/7/31)
Recommended Model: PMT-12V50W2BA
** EOL **
PMT-12V50W1AG, PMT-12V50W1AH, PMT-12V50W1AAB
** NRND (Not Recommended for New Designs) **
PMT-12V50W1AA (Last Buy Date: 2026/7/31~2027/7/31)
Recommended Model: PMT-12V50W2BA
12V
50W
4.17A
90-264Vac
98 x 98 x 38 mm
3.86” x 3.86” x 1.50”
0.23 kg (0.51 lb)
|
Output Current
4.17A
|
|
Output Voltage
12V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
11-14Vdc
|
|
Output Power
50W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5%typ. (@ 85-264Vac input, 100% load)
|
|
Load Regulation
< 1%typ. (@ 85-264Vac input, 0-100% load)
|
|
PARD
< 100mVpp @ 0°C to 50°C,
< 150mVpp @ -10°C to 0°C |
|
Start-up Time
< 2500ms @ nominal input (100% load)
|
|
Hold-up Time
> 16.7ms @ 115Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load (Slew Rate: 0.1A/µS)
|
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 30ms @ nominal input (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
90-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 1.10A @ 115Vac,
< 0.70A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 83.0% @ 115Vac & 230Vac
|
|
Inrush Current
< 30A @ 115Vac,
< 60A @ 230Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
Conform to EN61000-3-2
|
|
Leakage Current
< 1mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
SGCC / Aluminium
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.23 kg (0.51 lb)
|
Dimensions
98 x 98 x
38 mm
3.86” x 3.86” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% /°C
|
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
|
Vibration (Non-Operating)
IEC60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
16V, +10% / -5%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Overload / Overcurrent
> 120% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
Non-Latching (Auto-Recovery)
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IPX0
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
(I/P: 100Vac, O/P: 100% Load, Ta: 35°C) |
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Case Temperature Rise
-
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart :EN 60950-1, EN 62368-1
UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) CB scheme :IEC 60950-1, IEC 62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac Output to Ground: 0.5 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
48V
750W
0-15.63A
85-264 Vac
24V
1200W
0-50A
85-264 Vac
48V
211.2W
4.4A
180-264 Vac
24V
150W
6.25A
180-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.