Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
15V
51W
3.4A
85-264Vac
98 x 98 x 38 mm
3.86” x 3.86” x 1.50”
0.23 kg (0.51 lb)
** NRND **
PMT-15V50W1AA, PMT-15V50W1AG, PMT-15V50W1AH
Recommended Model: PMT-15V50W2BA
| Model | Description |
|---|---|
| PMT-15V50W1AG | Enclosed, front face connector |
| PMT-15V50W1AH | Enclosed, harness connector |
** NRND **
PMT-15V50W1AA, PMT-15V50W1AG, PMT-15V50W1AH
Recommended Model: PMT-15V50W2BA
15V
51W
3.4A
85-264Vac
98 x 98 x 38 mm
3.86” x 3.86” x 1.50”
0.23 kg (0.51 lb)
| Model | Description |
|---|---|
| PMT-15V50W1AG | Enclosed, front face connector |
| PMT-15V50W1AH | Enclosed, harness connector |
|
Output Current
3.4A
|
|
Output Voltage
15V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
13.5-16.5Vdc
|
|
Output Power
51W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5% typ. (@ 115Vac & 230Vac input, 100% input)
|
|
Load Regulation
< 0.5% typ. (@ 115Vac & 230Vac input, 0-100% input)
|
|
PARD
< 150mVpp @ 25°C to 50°C,
< 300mVpp @ -10°C to 0°C |
|
Start-up Time
1,200ms typ.@ 115Vac,
500ms typ. @ 230Vac (100% load) |
|
Hold-up Time
20ms typ. @ 115Vac, 100ms typ. @ 230Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% (1000mVp-p)@ 0-100% load (Slew Rate: 0.1A/µS)
|
|
Start-up with Capacitive Loads
8,000μF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 30ms @ 115Vac & 230Vac (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 1.10A @ 115Vac, < 0.65A @ 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
85.5% typ. @ 230Vac
|
|
Inrush Current
45A typ. @ 230Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 0.5mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium / SGCC
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.23 kg (0.51 lb)
|
Dimensions
98 x 98 x
38 mm
3.86” x 3.86” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 1.33% / V (80% load @ 85Vac) |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
17.25-20.25V, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery) |
|
Overload / Overcurrent
110-150% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery) |
|
Over Temperature
Non-Latching (Auto-Recovery)
|
|
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs as per Telcordia SR-332 I/P: 100Vac, O/P: 100% Load, Ta: 35°C)
|
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart:EN 60950-1, EN/BS EN 62368-1
UL/cUL recognized:UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) CB scheme:IEC 60950-1, IEC 62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
48V
158.4W
3.3A
180-264 Vac
48V
76.8W
1.6A
180-264 Vac
24V
52.8W
2.2A
180-264 Vac
48V
1200W
0-25A
85-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.