Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
350.4W
14.6A
90-132Vac, 180-264Vac (Selectable by Switch)
215 x 115 x 50 mm
8.46” x 4.53” x 1.97”
0.82 kg (1.81 lb)
** NRND **
PMT-24V350W1AG
** Discontinued Product **
PMT-24V350W1AM
Recommended Model: PMT-24V350W2BR
** NRND **
PMT-24V350W1AG
** Discontinued Product **
PMT-24V350W1AM
Recommended Model: PMT-24V350W2BR
24V
350.4W
14.6A
90-132Vac, 180-264Vac (Selectable by Switch)
215 x 115 x 50 mm
8.46” x 4.53” x 1.97”
0.82 kg (1.81 lb)
|
Output Current
14.6A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
20.0-26.4Vdc
|
|
Output Power
350.4W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5% typ
|
|
Load Regulation
± 0.5% typ.
|
|
PARD
< 150mVpp @ 25°C
|
|
Start-up Time
< 1000ms @ nominal input (100% load, 25°C)
|
|
Hold-up Time
> 16ms @ 115Vac,
> 20ms @ 230Vac (100% load) |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 10-50% load and 50-100% load
|
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 50ms @ nominal input (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-120Vac, 200-240Vac (Selectable by Switch)
|
|
Input Voltage Range
90-132Vac, 180-264Vac (Selectable by Switch)
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 7.00A @ 115Vac,
< 4.00A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 87.0% @ 230Vac
|
|
Inrush Current
< 50A @ 115Vac,
< 60A @ 230Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 3.5mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Forced Cooling
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 52dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
AWG 20-12
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.82 kg (1.81 lb)
|
Dimensions
215 x 115 x
50 mm
8.46” x 4.53” x 1.97” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S? (2.5G peak); 90 min per axis for all X, Y, Z direction
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 3% / V < 200Vac de-rate power by 3% / V |
|
Operating Humidity
5-95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC60068-2-27, 50G for a duration of 11ms,
3 times per direction, 18 times in total |
|
Vibration (Non-Operating)
IEC60068-2-6, Random: 5Hz to 500Hz @ 2.09G peak; 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
< 32.4V, SELV Output, Latch Mode
|
|
Overload / Overcurrent
< 25A of rated load current, Hicc-up Mode,
Non-Latching (Auto-Recovery) |
|
Over Temperature
Hicc-up Mode, Non-Latching
(Auto-Recovery when the fault is removed) |
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IPX0
|
|
Protection Against Shock
Class I with PE connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)
CB scheme: UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) IEC 60950-1, IEC 62368-1 |
|
CE
-
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac Output to Ground: 0.5 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with 2016 No. 1101. The Electrical Equipment (Safety) Regulations 2016 and 2016 No. 1091 The Electromagnetic Compatibility Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, FCC Title 47: Class A (With Delta EMI filter P/N: 10DKAW5) |
|
Immunity
EN/BS EN 55024
|
|
Harmonic Current Emissions
NA
|
|
Voltage Fluctuation and Flicker
-
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
2500W
0-104.2A
85-264 Vac
48V
2500W
0-52.1A
85-264 Vac
48V
1200W
0-25A
85-264 Vac
36V
1000W
28A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.