Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
5V
300W
60A
90-132Vac, 180-264Vac (Selectable by Switch)
215 x 115 x 50 mm
8.46” x 4.53” x 1.97”
0.81 kg (1.79 lb)
** Discontinued Product **
PMT-5V350W1AM
Recommended Model: PMR-5V320WDAA
** NRND **
PMT-5V350W1AMA, PMT-5V350W1AMB, PMT-5V350W1AMC, PMT-5V350W1AME, PMT-5V350W1AN


| Model | Description |
|---|---|
| PMT-5V350W1AN | Front face connector |
| PMT-5V350W1AMA | Terminal block with connector cover |
| PMT-5V350W1AMB | Terminal block, conformal coating |
| PMT-5V350W1AMC | Terminal block with connector cover, conformal coating |
** Discontinued Product **
PMT-5V350W1AM
Recommended Model: PMR-5V320WDAA
** NRND **
PMT-5V350W1AMA, PMT-5V350W1AMB, PMT-5V350W1AMC, PMT-5V350W1AME, PMT-5V350W1AN


5V
300W
60A
90-132Vac, 180-264Vac (Selectable by Switch)
215 x 115 x 50 mm
8.46” x 4.53” x 1.97”
0.81 kg (1.79 lb)
| Model | Description |
|---|---|
| PMT-5V350W1AN | Front face connector |
| PMT-5V350W1AMA | Terminal block with connector cover |
| PMT-5V350W1AMB | Terminal block, conformal coating |
| PMT-5V350W1AMC | Terminal block with connector cover, conformal coating |
|
Output Current
60A
|
|
Output Voltage
5V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
4.50-5.50Vdc
|
|
Output Power
300W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5% typ
|
|
Load Regulation
± 2.5% typ
|
|
PARD
< 150mVpp
|
|
Start-up Time
< 1000ms @ nominal input (100% load)
|
|
Hold-up Time
> 16ms @ 115Vac,
> 20 ms @ 230Vac |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 1000mVpp @ 10-50% load and 50-100% load
|
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-120Vac, 200-240Vac (Selectable by Switch)
|
|
Input Voltage Range
90-132Vac, 180-264Vac (Selectable by Switch)
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 7.00A @ 115Vac,
< 4.00A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 76.0% @ 230Vac
|
|
Inrush Current
< 40A @ 115Vac,
< 60A @ 230Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 3.5mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
-
|
|
|
Cooling System
Forced Cooling
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.81 kg (1.79 lb)
|
Dimensions
215 x 115 x
50 mm
8.46” x 4.53” x 1.97” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S? (2.5G peak); 90 min per axis for all X, Y, Z direction
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-20°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 4% /°C
> 60°C de-rate power by 1% /°C < 100Vac de-rate power by 3%/V, < 200Vac de-rate power by 1.5%/V |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms peak; 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
< 5.75~7.50V, SELV Output, Latch Mode
|
|
Overload / Overcurrent
> 105~175% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File no. E131881), CB scheme to IEC 60950-1
|
|
CE
-
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV (EN 60950-1)
|
|
Maritime
-
|
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
CISPR32, EN55032, FCC Title 47: Class A (Test with Delta EMI filter P/N: 10DKAW5)
|
|
Immunity
-
|
|
Harmonic Current Emissions
-
|
|
Voltage Fluctuation and Flicker
-
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
2500W
0-104.2A
85-264 Vac
24V
1200W
0-50A
85-264 Vac
12V
600W
50A
90-132Vac, 180-
48V
1000W
21A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.