Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
19.5V
150W
7.7A
90-264Vac
160 x 76.2 x 25.8 mm
6.30” x 3.00” x 1.02”
0.41 kg (0.90 lb)
19.5V
150W
7.7A
90-264Vac
160 x 76.2 x 25.8 mm
6.30” x 3.00” x 1.02”
0.41 kg (0.90 lb)
|
Output Current
7.7A
|
|
Output Voltage
19.5V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
150W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5%
|
|
Load Regulation
± 4.5%
|
|
PARD
380 mV pk-pk @0 to 40°C
760 mV pk-pk @-10 to 0°C |
|
Start-up Time
1000 ms @ 115Vac
500 ms @ 230Vac |
|
Hold-up Time
16ms @ nominal input , full load
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
40ms @ nominal input, full load
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
90-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
1.8 A @115Vac
0.9 A @230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
79% @ 115Vac & 230Vac
|
|
Inrush Current
No damage
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
0.25mA @ 240Vac/50Hz
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
PC
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
C6
|
|
|
Output Terminal
Barrel type : O.D: 6.0mm, I.D: 3.5mm, length: 11.5mm
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.41 kg (0.90 lb)
|
Dimensions
160 x 76.2 x
25.8 mm
6.30” x 3.00” x 1.02” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +60°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
>40°C de-rated by 2.5%/°C
|
|
Operating Humidity
5%-95% RH (non-condensing)
|
|
Shock Test (Non-Operating)
50G, 11ms, 1 shock for each direction
|
|
Vibration (Non-Operating)
5-500Hz, 2.09Grms, 20mins, one cycle for each three axis
|
|
Storage Humidity
-
|
|
Operating Altitude
5,000 meters (16400 feet)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Overvoltage
27V, Latch mode
|
|
Overload / Overcurrent
120-180% , Latch
|
|
Over Temperature
Latch Mode
|
|
Short Circuit
Latch Mode
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 300,000 hrs. per Telcordia SR-332 at Input: 115Vac, Output: 100% load, Ta: 25°C
|
|
Expected Cap Life Time
5 years (50% load @ 25°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC/EN 60950-1 ; IEC/UL/EN 62368-1
BSMI CNS14336-1 CCC GB4943.1 PSE J62368-1 KC K60950-1 |
|
CE
Comply with EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
I/P to O/P: 3000Vac
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
CISPR/EN/BS EN 55032 Class B
BSMI CNS13438 GB/T9254 KN32 |
|
Immunity
EN/BS EN 55024; KN35
|
|
Harmonic Current Emissions
Class D; GB17625.1
|
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
5V,9V,15V,20V
45W
3A,3A,3A,2.25A
90-264 Vac
5V,9V,12V,15V,20V
30W
3A,3A,2.5A,2A,1.5A
90-264 Vac
5V,9V,15V,20V
65W
3A,3A,3A,3.25A
90-264 Vac
5V,9V,15V,20V
65W
3A,3A,3A,3.25A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.