24V
240W
10A
85-276Vac
124 x 60 x 117 mm
4.88” x 2.36” x 4.61”
0.94 kg (2.07 lb)
24V
240W
10A
85-276Vac
124 x 60 x 117 mm
4.88” x 2.36” x 4.61”
0.94 kg (2.07 lb)
|
Output Current
10A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
24-28Vdc
|
|
Output Power
240W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
10mV Max. (@ 85-276Vac input, 100% load)
|
|
Load Regulation
100mV Max. (@ 85-276Vac input, 0-100% load)
|
|
PARD
50mVpp Max.
|
|
Start-up Time
800ms Max. @ 100Vac,
650ms Max. @ 120Vac, 340ms Max. @ 230Vac |
|
Hold-up Time
46ms Typ. @ 100Vac & 120Vac & 230Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load
Slew rate 0.1A/µs (@ 5Hz, 50Hz & 1kHz, 50% Duty Cycle) |
|
Start-up with Capacitive Loads
10,000µF Max.
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
100ms Max. @ 100Vac & 120Vac & 230Vac (0µF, 24V, 10A)
120ms Max. @ 100Vac & 120Vac & 230Vac (10,000µF, 24V, 10A) |
|
Power Boost Duration
5 seconds Typ.
7 seconds Max. |
|
Power Boost Recovery Time
14 seconds Typ.
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-276Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
110-300Vdc
|
|
DC Input Voltage Range
88-375Vdc
|
|
Input Current
10.0A Max. @ 100Vac & 120Vac & 230Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
92.64% Typ. @ 100Vac, 93.44% Typ. @ 120Vac, 94.84% Typ. @ 230Vac
|
|
Inrush Current
10.0A Max. @ 100Vac & 120Vac & 230Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 Typ. @ 100Vac, 0.98 Typ. @ 120Vac, 0.95 Typ. @ 230Vac
|
|
Leakage Current
(Enclosure to Neutral)
< 0.25mA / 0.54mA @ 110Vac, 50Hz, TN/TT system / IT system < 0.38mA / 0.79mA @ 132Vac, 50Hz, TN/TT system / IT system < 0.74mA / 1.29mA @ 264Vac, 50Hz, TN/TT system / IT system |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
0% load:
2.30W Typ. @ 100Vac, 2.34W Typ. @ 120Vac, 2.43W Typ. @ 230Vac 4.40W Max. @ 100Vac, 4.90W Max. @ 120Vac, 6.10W Max. @ 230Vac 100% load: 19.12W Typ. @ 100Vac, 16.91W Typ. @ 120Vac, 13.10W Typ. @ 230Vac 23.50W Max. @ 100Vac, 20.10W Max. @ 120Vac, 17.50W Max. @ 230Vac |
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED (DC OK) and Red LED (Overload)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
3 Pins (Rated 600V/35A)
|
|
|
Output Terminal
6 Pins (Rated 300V/28A)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
|
Wire
Input: AWG 18-8
Output: AWG: 16-12 |
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.94 kg (2.07 lb)
|
Dimensions
124 x 60 x
117 mm
4.88” x 2.36” x 4.61” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-25°C to +70°C (Cold start -40°C)
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Vertical Mounting: > 60°C de-rate power by 2.5% / °C
Horizontal Mounting: > 50°C de-rate power by 2.5% / °C |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.) for ITE application
0 to 2,500 Meters (8,200 ft.) for Industrial application |
|
Pollution Degree
2
|
|
Bump Test (Operating)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
|
|
Over Voltage Category
III
According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
|
Corrosion
-
|
|
Overvoltage
28.8 – 35.2V, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery) |
|
Overload / Overcurrent
> 150% of rated load current, Constant current limit, Auto-Recovery when the fault is removed
|
|
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
|
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP20
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
1,476,000 hrs. (I/P: 100Vac, O/P: 24V, 10A, Ta: 25°C)
771.000 hrs. (I/P: 100Vac, O/P: 24V, 10A, Ta: 40°C) |
|
Expected Cap Life Time
131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 10A, Ta: 25°C)
58,000 hrs. @ 100Vac (O/P: 24V, 10A, Ta: 40°C) 87,600hrs. @ 230Vac (O/P: 24V, 10A, Ta: 40°C) 131,400 hrs. @ 100Vac & 230Vac (O/P: 24V, 5A, Ta: 40°C) |
|
Safety Certificate
-
|
|
Electrical Safety
SIQ Bauart: EN 62368-1, EN 61558-1, EN 61558-2-16, EN 61010-1, EN 61010-2-201
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1, IEC 61558-1, IEC 61558-2-16, IEC 61010-1, IEC 61010-2-201 KC: K 60950-1 UKCA: BS EN 62368-4, BS EN 61558-1, BS EN 61558-2-16, BS EN 61010-1, BS EN 61010-2-201 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input / Output: 4.54 KVac
Input / PE: 2.5 KVac Input / DC OK relay contact: 4.54 KVac (Recommend to connect DC OK pins together with output pins) Output / PE: 1.5 KVac Output / DC OK relay contact: 0.5 KVac DC OK relay contact / PE: 1.5 KVac |
|
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355),
CSA: CSA C22.2 No. 107.1-01 (File No. 181564) |
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
EN/BS EN 60204-1 (over voltage category III)
|
|
Electrical Equipment for Use in Electrical Power Installations
IEC/EN/BS EN 62477-1 / IEC 62103
|
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
|
Maritime
DNV GL: Germanischer Lloyd classified
ABS: American Bureau for Shipping) PDA Environmental category: C, EMC2 |
|
Material and Parts
-
|
|
Isolation Resistance
> 5 MOhm (Input to Output, 500 Vdc)
|
|
PE Resistance
< 0.1 Ohm
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
(CE & RE)
Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, KN 32, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B |
|
Immunity
Generic Standards: EN/BS EN 55024, KN 35, EN/BS EN 61000-6-2
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
12V
240W
20A
85-277 Vac (305
48V
120W
2.5A
3 x 340-575 Vac
48V
960W
20A
85-277 Vac
24V
240W
10A
85-277 Vac (305