Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
260-500V
1000W
1.4A
198-440Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
| Model | Description |
|---|---|
| EUCO-1K0140GLA | Control Interface: DALI 2 |
260-500V
1000W
1.4A
198-440Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
| Model | Description |
|---|---|
| EUCO-1K0140GLA | Control Interface: DALI 2 |
|
Output Current
1.4A
|
|
Output Voltage
260-500V
|
|
Output Voltage Range
260-500Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
1000W
|
|
Output Current Adjustment Range
0.5-1.4A
|
|
Max Output Voltage
600Vdc
|
|
Buffering Time
-
|
|
Line Regulation
±1%
|
|
Load Regulation
±3%
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
500W per channel, 1.0kW total
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 2s
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Nominal Input Voltage
220-400Vac
|
|
Input Voltage Range
198-440Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
4.8A @220 Vac
2.7A @400 Vac |
|
Input Power (Standby Mode)
<0.5W at 230Vac,in compliance with Erp (EU) 2019/2020
|
|
Efficiency at 100% load
95.2% @220 Vac
96% @400 Vac |
|
Inrush Current
<=25 A, pulse width<8mS @400Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.95 @ 198-440Vac, full load
|
|
Leakage Current
< 1mA @400Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
<20% @ 198-440Vac, full load
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminum case
|
|
|
Indicator
-
|
|
|
Cooling System
Natural Convection
|
|
|
Input Terminal
Wago 264-103: With the sign of L, N, PE
|
|
|
Output Terminal
Wago 264-111: With the sign of PE, NTC, V3+ V3-, V2+, V2-, V1+, V1-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
5.4 kg (11.90 lb)
|
Dimensions
500 x 152 x
77 mm
19.69” x 5.98” x 3.03” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40 ~+50°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10 to 100% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
|
Storage Humidity
10 to 100% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Overvoltage
Output voltage limited, 600Vdc
|
|
Overload / Overcurrent
Output power limited, 520W(Typ)
|
|
Over Temperature
Driver Over Temperature: Output power derating, not less than 20% in the worst case, auto-recovery when the fault is clear.
LED Fixtures Over Temperature: Output power derating, not less than 20% in the worst case, auto-recovery when the fault is clear |
|
Short Circuit
Auto-Recovery when the fault is removed
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
475khrs. at ta=+45°C Telcordia SR-332
|
|
Expected Cap Life Time
50,000 hours applicable for 220Vac to 400Vac(50/60Hz) @100% of load, @ ta 45°C
|
|
Safety Certificate
ENEC
—IEC/EN61347-2-13 electronic control gear for LED Modules, independent type. —IEC/EN62384 DC or AC supplied electronic control gear for LED modules. CE Declaration of Conformity. CB report. |
|
Electrical Safety
-
|
|
CE
-
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Radiated Emission EN55015 Test at 230Vac/400Vac
Conducted Emission EN55015 Test at 230Vac/400Vac |
|
Immunity
-
|
|
Harmonic Current Emissions
EN61000-3-2
|
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
150-550V
1650W
2A
187-528 Vac
60-200V
130W
0.2-1.05A
198-264Vac
80-310V
170W
0.2-1.05A
198-264Vac
150-550V
1800W
1A
180-528 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.