Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
50-370V
1200W
1.2A
187-528 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.1 kg (11.24 lb)
50-370V
1200W
1.2A
187-528 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.1 kg (11.24 lb)
|
Output Current
1.2A
|
|
Output Voltage
50-370V
|
|
Output Voltage Range
50-370Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
1200W
|
|
Output Current Adjustment Range
0.15-1.2A
|
|
Max Output Voltage
370Vdc
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
208-480 Vac
|
|
Input Voltage Range
187-528 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50/60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
5.7A Typ. At 1-ph L/N 220Vac, 1.2A* 250V=300W per channel, total 1200W
3.1A Typ. At 2-ph L1/L2 400Vac, 1.2A* 250V=300W per channel, total 1200W |
|
Input Power (Standby Mode)
0.5W At 220Vac/50Hz, Dim OFF, in compliance with Erp(EU) 2019/2020
|
|
Efficiency at 100% load
95% Typ. At 1-ph L/N 220Vac, 1.2A* 250V=300W per channel, total 1200W
96% Typ. At 2-ph L1/L2 400Vac, 1.2A* 250V=300W per channel, total 1200W |
|
Inrush Current
12A At 220Vac,50%Apk to 50%Apk time: <2 ms
20A At 400Vac,50%Apk to 50%Apk time: < 2ms |
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 Typ. At 1-ph L/N 220Vac, Full load
0.99 Typ. At 2-ph L1/L2 400Vac, Full load |
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
6% Typ. At 1-ph L/N 220Vac, total Pout=1200W Load
12% At 2-ph L1/L2 400Vac, total Pout=1200W Load |
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminum case, Dark Gray, compliance with C5 environment (ISO 9223)
|
|
|
Indicator
-
|
|
|
Cooling System
Natural Convection
|
|
|
Input Terminal
With the sign of L1, L2, PE
|
|
|
Output Terminal
With the sign of PE, NTC, V2+, V2-, V1+, V1-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
5.1 kg (11.24 lb)
|
Dimensions
500 x 152 x
77 mm
19.69” x 5.98” x 3.03” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40 ~+50°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10% to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
|
Storage Humidity
10% to 90% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
-
|
|
Overload / Overcurrent
-
|
|
Over Temperature
-
|
|
Short Circuit
-
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP66 (EN 60529)
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
475khrs. at Ta=+45°C Telcordia SR-332
|
|
Expected Cap Life Time
50,000 hours applicable for 220Vac to 480Vac(50/60Hz)@100% of load, Ta=50°C (Tcase=80°C)
|
|
Safety Certificate
ENEC:
EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN 61347-2-13:2014, EN 61347-2-13/A1:2017 IEC/EN 62384:2020 CB: EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN 61347-2-13:2014, EN 61347-2-13/A1:2017 RCM: AS/NZS 61347-1: 2016+A1 AS 61347-2-13: 2018 UL: UL Compliant ANSI / UL8750 2nd Ed. CSA C22.2 No.250.13, 4th Ed. CCC: GB 19510.1 GB 19510.14 |
|
Electrical Safety
-
|
|
CE
CE Declaration of Conformity.
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
BS EN 61347-2-13: 2014+A1:2017
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Radiated Emission: EN55015, GB/T17743, FCC Part 15, Subpart B
Conducted Emission: EN55015, GB/T17743, FCC Part 15, Subpart B |
|
Immunity
-
|
|
Harmonic Current Emissions
IEC/EN 61000-3-2, GB 17625.1
|
|
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
|
|
ESD Immunity
IEC/EN 61000-4-2
|
|
Radiated Immunity
-
|
|
EFT
IEC/EN 61000-4-4
|
|
Surge
(AC Mains)
IEC/EN 61000-4-5 - Common Mode: 10kV (L1 to Earth, L2 to Earth) - Differential Mode: 10kV (L1 to L2) |
|
Conducted Immunity
-
|
|
Magnetic Field
IEC/EN 61000-4-3
|
|
Voltage Dips
IEC/EN 61000-4-11
|
|
Component Power Supply for General Use
-
|
150-550V
1200W
2A
187-528 Vac
150-550V
1650W
2A
187-528 Vac
150-550V
1800W
2A
187-528 Vac
200-550V
600W
2A
198-440Vac
200-550V
600W
2A
198-440Vac