Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
150-550V
1400W
2A
198-440 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
| Model | Description |
|---|---|
| EUCO-1K4200GIA | Control Interface: DALI-2 & D4i |
150-550V
1400W
2A
198-440 Vac
500 x 152 x 77 mm
19.69” x 5.98” x 3.03”
5.4 kg (11.90 lb)
| Model | Description |
|---|---|
| EUCO-1K4200GIA | Control Interface: DALI-2 & D4i |
|
Output Current
2A
|
|
Output Voltage
150-550V
|
|
Output Voltage Range
150-550Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
1400W
|
|
Output Current Adjustment Range
0.7-2A
|
|
Max Output Voltage
600Vdc
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
220-400 Vac
|
|
Input Voltage Range
198-440 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50/60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
7A At 220Vac, 25°C, 1400W output
4A At 400Vac, 25°C, 1400W output |
|
Input Power (Standby Mode)
0.3W At 230Vac, Dim OFF, in compliance with Erp (EU) 2019/2020
0.8W At 400Vac, Dim OFF |
|
Efficiency at 100% load
At 220Vac~400Vac,100% load
|
|
Inrush Current
15A At 220Vac,50%Apk to 50%Apk time: 2ms
25A At 400Vac,50%Apk to 50%Apk time: 2ms |
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 At 220Vac, 25°C, 2100W output
0.97 At 400Vac, 25°C, 2100W output |
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
6% At 220Vac, 25°C, 350V/2A *3 channels output
10% At 400Vac, 25°C, 350V/2A *3 channels output |
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminum case, Dark Gray, compliance with C5 environment (ISO 9223)
|
|
|
Indicator
-
|
|
|
Cooling System
Natural Convection
|
|
|
Input Terminal
With the sign of L1, L2, PE
|
|
|
Output Terminal
With the sign of PE, NTC, V3+ V3-, V2+, V2-, V1+, V1-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
5.4 kg (11.90 lb)
|
Dimensions
500 x 152 x
77 mm
19.69” x 5.98” x 3.03” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40 ~+50°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10% to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
|
Storage Humidity
10% to 90% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
-
|
|
Overload / Overcurrent
-
|
|
Over Temperature
-
|
|
Short Circuit
-
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP66
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
475khrs. at Ta=+45°C Telcordia SR-332
|
|
Expected Cap Life Time
50,000 hours applicable for 220Vac to 400Vac(50/60Hz) @100% of load, @ Ta 45°C
|
|
Safety Certificate
ENEC:
EN 61347-2-13:2014, EN 61347-2-13/A1:2017 EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN IEC 62384:2020 UL Compliant ANSI / UL8750 2nd Ed., CSA C22.2 No.250.13, 4th Ed. RCM:AS 61347-2-13: 2018 AS/NZS 61347-1: 2016+A1 CB report. |
|
Electrical Safety
-
|
|
CE
EN 61347-2-13:2014, EN 61347-2-13/A1:2017
CE Declaration of Conformity. |
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
BS EN 61347-2-13: 2014+A1:2017
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Radiated Emission EN55015
Conducted Emission EN55015 |
|
Immunity
-
|
|
Harmonic Current Emissions
EN61000-3-2
|
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
|
ESD Immunity
EN 61000-4-2
|
|
Radiated Immunity
-
|
|
EFT
EN 61000-4-4
|
|
Surge
(AC Mains)
EN 61000-4-5 - Common Mode: 10kV4 (Line to Earth, Neutral to Earth) - Differential Mode: 10kV4 (Line to Neutral) |
|
Conducted Immunity
-
|
|
Magnetic Field
EN 61000-4-3
|
|
Voltage Dips
EN 61000-4-11
|
|
Component Power Supply for General Use
-
|
260-500V
1000W
1.4A
198-440Vac
260-500V
1500W
1.4A
198-440Vac
250-550V
2100W
2A
198~440 Vac
200-550V
600W
2A
198-440Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.