150-550V
1800W
1A
180-528 Vac
345 x 152 x 62 mm
13.58” x 5.98” x 2.44”
5.4 kg (11.90 lb)
150-550V
1800W
1A
180-528 Vac
345 x 152 x 62 mm
13.58” x 5.98” x 2.44”
5.4 kg (11.90 lb)
|
Output Current
1A
|
|
Output Voltage
150-550V
|
|
Output Voltage Range
150-550Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
1800W
|
|
Output Current Adjustment Range
0.7-2A
|
|
Max Output Voltage
600Vdc
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
200-480 Vac
|
|
Input Voltage Range
180-528 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50/60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
7.2A at 220Vac, 25°C, 1500W output
4.0A At 480Vac, 25°C, 1800W output |
|
Input Power (Standby Mode)
0.5W at 230Vac/50Hz, Dim OFF,
in compliance with Erp(EU) 2019/2020 |
|
Efficiency at 100% load
97% at 220Vac, Io=3A @ Pout=1500W
98.05% at 400Vac, Io=3.27A @ Pout=1800W |
|
Inrush Current
14A at 220Vac,10%Ipeak to 10% Ipeak: <5 ms
25A at 480Vac,480Vac, 10%Ipeak to 10% Ipeak: <5ms compliant with NEMA410-2015 |
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 typ. at 220Vac/50Hz, Pout=1500W
0.99 typ. at 400Vac/50Hz, Pout=1800W |
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
10% at 220Vac/50Hz, Pout=1500W output
15% at 400Vac/50Hz, Pout=1800W |
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
Aluminum alloy case, dark gray
|
|
|
Indicator
-
|
|
|
Cooling System
Natural Convection
|
|
|
Input Terminal
L1/L, L2/N, PE
|
|
|
Output Terminal
PE, V+, V-, NTC,
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
5.4 kg (11.90 lb)
|
Dimensions
345 x 152 x
62 mm
13.58” x 5.98” x 2.44” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40 ~+50°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10% to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
|
Storage Humidity
5% to 95% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
-
|
|
Overload / Overcurrent
-
|
|
Over Temperature
-
|
|
Short Circuit
-
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP66
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
475khrs. at Ta=+45°C Telcordia SR-332
|
|
Expected Cap Life Time
50,000 hours applicable for 277Vac to 480Vac(50/60Hz)@ 1800W and
220 to 240Vac(50Hz)@ 1500W, Ta=45℃(Tcase=80℃), |
|
Case Temperature Rise
-
|
|
Safety Certificate
ENEC:
EN 61347-2-13:2015, EN 61347-1-2015/A1:2021 EN 61347-2-13:2014, EN 61347-2-13:2014/A1:2017 EN IEC 62384:2020 CB report: EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN 61347-1:2015/AMD1:2017 IEC 61347-2-13:2014, IEC 61347-2-13:2014/AMD1:2016 UL8750 2nd Ed., CSA C22.2 No.250.13, 5th Ed. RCM: AS/NZS 61347.1:2016+A1, AS 61347.2.13:2018 CCC: GB 19510.1, GB 19510.14 |
|
Electrical Safety
-
|
|
CE
CE Declaration of Conformity.
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
BS EN 61347-2-13: 2014+A1:2017
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
Radiated Emission EN55015, GB/T17743, FCC 47CFR Part 15 Subpart B, Class B, ANSI C63.4, ICES-005
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC 61000-3-2, GB 17625.1
|
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
|
ESD Immunity
EN 61000-4-2, IEC/EN 61547
|
|
Radiated Immunity
-
|
|
EFT
EN 61000-4-4
|
|
Surge
(AC Mains)
IEC 61000-4-4, IEC/EN 61547 |
|
Conducted Immunity
-
|
|
Magnetic Field
EN 61000-4-3, IEC/EN 61547
|
|
Voltage Dips
EN 61000-4-11, IEC/EN 61547
|
|
Component Power Supply for General Use
-
|
150-550V
1650W
2A
187-528 Vac
12V
20W
1.7A
108-305Vac
200-550V
600W
2A
198-440Vac
200-550V
600W
2A
198-440Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.