Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
96W
4A
108-305Vac
241.3 x 43.1 x 30 mm
9.50” x 1.70” x 1.18”
0.535 kg (1.18 lb)
24V
96W
4A
108-305Vac
241.3 x 43.1 x 30 mm
9.50” x 1.70” x 1.18”
0.535 kg (1.18 lb)
|
Output Current
4A
|
|
Output Voltage
24V
|
|
Output Voltage Range
22.8-25.2Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
96W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 1%
|
|
Load Regulation
± 3%
|
|
PARD
-
|
|
Start-up Time
< 1s
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 50ms
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
120-277Vac
|
|
Input Voltage Range
108-305Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50/60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
1.9A @ 120Vac
1.2A @ 277Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
87% typ. @ 120Vac
89% typ. @ 277Vac |
|
Inrush Current
-
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
Metal sheet, Color: White
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
Line: Black, Neutral: White,
Wire Length 11.81inch (300mm) UL1316 or UL1015 |
|
|
Output Terminal
Positive: Red, Negative: Black, Wire Length 11.81inch
(300mm) UL1316 or UL1007 |
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
24dBA (30cm distance)
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.535 kg (1.18 lb)
|
Dimensions
241.3 x 43.1 x
30 mm
9.50” x 1.70” x 1.18” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to + 60°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10 to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
5 to 95% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
Auto-Recovery when the fault is removed
|
|
Overload / Overcurrent
-
|
|
Over Temperature
Latch mode
|
|
Short Circuit
Auto-Recovery when the fault is removed
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
UL: UL 8750, Class P, type “HL”, UL1310 Class 2
|
|
CE
IEC/EN 62368-1
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Compliance to 47 CFR FCC Part 15, Subpart B, Class A
|
|
Immunity
Compliance to EN 55035
|
|
Harmonic Current Emissions
IEC 61000-3-2 Class A
|
|
Voltage Fluctuation and Flicker
-
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
60W
2.5A
90-266Vac
150-550V
1800W
1A
180-528 Vac
80-310V
170W
0.2-1.05A
198-264Vac
200-550V
600W
2A
198-440Vac