24V
200W
8.33A
90-264Vac
101.9 x 51.1 x 36.6 mm
4.01” x 2.01” x 1.44”
0.20 kg (0.44 lb)
** NRND **
Recommended Model:
MEP-200A24J BNA
** NRND **
Recommended Model:
MEP-200A24J BNA
24V
200W
8.33A
90-264Vac
101.9 x 51.1 x 36.6 mm
4.01” x 2.01” x 1.44”
0.20 kg (0.44 lb)
|
Output Current
8.33A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
200W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
±0.5%
|
|
Load Regulation
±1%
|
|
PARD
-
|
|
Start-up Time
2000ms @ 115Vac
|
|
Hold-up Time
12ms @ 115Vac, tested with 140W load
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
±5% @ 50-100% load
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
90-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
2.5A
|
|
Input Power (Standby Mode)
0.5W @ 115Vac/60Hz, 230Vac/50Hz
|
|
Efficiency at 100% load
92%@115Vac/60Hz
93%@230Vac/50Hz |
|
Inrush Current
60A @ 230Vac, cold start
|
|
Charging Time
-
|
|
Power Factor at 100% load
0.95 @ 115V/50Hz, 230V/50Hz, full load
|
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
NA
|
|
|
Indicator
-
|
|
|
Cooling System
-
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.20 kg (0.44 lb)
|
Dimensions
101.9 x 51.1 x
36.6 mm
4.01” x 2.01” x 1.44” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
Absolute Max -10°C to +70°C, supported power linearly de-rate from
50°C to 50% rated up to 70°C |
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
5-95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
125% of rated voltage, Latch Mode
|
|
Overload / Overcurrent
Main output 160% of rated current
Hiccup Mode(Non-Latching, Auto-Recovery) |
|
Over Temperature
Latch Mode
|
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 60950-1 CB report
IEC 62368-1 TUV 60950-1 UL 60950-1+CAN/CSA 60950-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1L 2013 + A12: 2014 & EN 60601-1-2: 2015 |
|
Medical Safety
IEC 60601-1 CB report
EN 60601-1 CAN/CSA-C22.2 No. 60601-1 ANSI/AAMI ES 60601-1 |
|
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground (1XMOPP): 1500 Vac Output to/Ground (1XMOPP): 1500 Vac (Type BF application rated) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002 (UK MDR 2002)
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
IEC 60950-1 CB report
IEC 62368-1 TUV 60950-1 UL 60950-1+CAN/CSA 60950-1 |
|
SIL3
-
|
|
Emission
EN/BS EN 55011, EN/BS EN 55032, FCC Title 47: Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC 61000-3-2, Meet Class D limit
|
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
12V
102W
8.5A
85-264Vac
24V
103.2W
4.3A
85-264Vac
12V
102W
8.5A
85-264Vac
48V
100.8W
2.1A
85-264Vac