Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V
102W
8.5A
85-264Vac
155 x 62 x 27 mm (Open Frame)
185 x 72 x 45 mm (Enclosed)
6.10" x 2.44" x 1.06" (Open Frame)
7.28" x 2.83" x 1.77" (Enclosed)
0.22 kg (0.49 lb) (Open Frame)
0.38 kg (0.84 lb) (Enclosed) (0.49 lb)
| Model | Description |
|---|---|
| PJ-12V100WERA | Enclosed, remote ON/OFF |
12V
102W
8.5A
85-264Vac
155 x 62 x 27 mm (Open Frame)
185 x 72 x 45 mm (Enclosed)
6.10" x 2.44" x 1.06" (Open Frame)
7.28" x 2.83" x 1.77" (Enclosed)
0.22 kg (0.49 lb) (Open Frame)
0.38 kg (0.84 lb) (Enclosed) (0.49 lb)
| Model | Description |
|---|---|
| PJ-12V100WERA | Enclosed, remote ON/OFF |
|
Output Current
8.5A
|
|
Output Voltage
12V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
10.8-13.2Vdc
|
|
Output Power
102W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
+/- 0.5%
|
|
Load Regulation
+/- 0.5%
|
|
PARD
-
|
|
Start-up Time
500ms typ. @ 100Vac (100% load)
|
|
Hold-up Time
30ms typ. @ 100Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-50% load and 50-100% load
(Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz) |
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
120-373 Vdc
|
|
Input Current
1.35 A typ. @ 100 Vac
0.55 A typ. @ 200 Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
89% typ. @ 100Vac,
91% typ. @ 200Vac |
|
Inrush Current
15A typ. @ 100Vac,
30A typ. @ 200Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 @ 100Vac,
0.98 @ 200Vac |
|
Leakage Current
0.2mA @ 100Vac,
0.4mA @ 240Vac |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
SGCC
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
JST B3P5-VH (LF)(SN)
|
|
|
Output Terminal
JST B8P-VH (LF)(SN)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
AWG 22-18
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.22 kg (0.49 lb) (Open Frame)
0.38 kg (0.84 lb) (Enclosed) (0.49 lb) |
Dimensions
155 x 62 x 27 mm (Open Frame)
185 x 72 x 45 mm (Enclosed) 6.10" x 2.44" x 1.06" (Open Frame) 7.28" x 2.83" x 1.77" (Enclosed) |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave:10 Hz to 500 Hz @ 2G;
10 min period, 60 min per axis for all X, Y, Z direction |
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Refer to datasheet (Engineering Data Fig.1.1~Fig.1.5 on Page8~10)
|
|
Operating Humidity
5 to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave 50G,11 ms, 3 shocks X, Y, and Z direction
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
13.8-16.8V, Latch Mode
|
|
Overload / Overcurrent
> 201% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
Latch Mode
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
|
|
Expected Cap Life Time
10 years (100 Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart: EN 62368-1 UL/cUL recognized: UL 62368-1 and CSA C22.2 No. 62368-1
CB scheme: IEC 62368-1 Design to meet DENAN at 100 Vac |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 2.0 KVac Output to Ground: 1.25 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
CISPR 32, EN/BS EN 55032, Comply with FCC Title 47: Class B
|
|
Immunity
EN/BS EN 55035
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A & Class D
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
151.2W
6.3A
85-264Vac
48V
504W
-
85-264 Vac
48V
153.6W
3.2A
85-264Vac
24V
600W
-
90-264 Vac