Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
600W
0-25A
90-264 Vac
127.0 x 76.2 x 39.0 mm
5.00” x 3.00” x 1.54”
0.435 KG (0.96 lb)
24V
600W
0-25A
90-264 Vac
127.0 x 76.2 x 39.0 mm
5.00” x 3.00” x 1.54”
0.435 KG (0.96 lb)
|
Output Current
0-25A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
24-28 Vdc
|
|
Output Power
600W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
0.5%
|
|
Load Regulation
2%
|
|
PARD
-
|
|
Start-up Time
900 ms typ. @ 90 Vac & 264 Vac
|
|
Hold-up Time
19 ms typ. @ 115 Vac & 230 Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 5-100% load change,
(50% duty @ 10 Hz & 10 KHz, 0.5 A/us slew rate) |
|
Start-up with Capacitive Loads
6,000 μF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
240 mVpp typ. (100% load)
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
11 ms typ. @ 90 Vac & 264Vac
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240 Vac
|
|
Input Voltage Range
90-264 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
5.8 A typ. @ 115 Vac, 2.9 A typ. @ 230 Vac
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
93.6% typ. @ 115 Vac
95.3% typ. @ 230 Vac |
|
Inrush Current
40 A typ. @ 264 Vac (Cold Start)
|
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.95 @ 115 Vac
> 0.93 @ 230 Vac |
|
Leakage Current
0.3 mA @ NC,
1.0 mA @ SFC |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
No load: 1.1 W typ. @ 264 Vac
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
Open Frame
|
|
|
Indicator
-
|
|
|
Cooling System
Convection / Force air
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
Input: JST: B2P3-VH(LF)(SN) or equivalent
Output: M4 x 0.7 Control: JST: S8B-PHDSS(LF)(SN) or equivalent |
|
|
Unit Weight
0.435 KG (0.96 lb)
|
Dimensions
127.0 x 76.2 x
39.0 mm
5.00” x 3.00” x 1.54” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-20 °C to +80 °C
|
|
Storage Temperature
-40 °C to +85 °C
|
|
Power De-rating
Temperature Power De-rating: > 50°C de-rate power by 1.67% / °C
Line Power De-rating: < 100Vac de-rate power by 0.83% / Vac |
|
Operating Humidity
5-95 % RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
5-500 Hz, 2.09 Grms, 20 minutes for each three axis
|
|
Storage Humidity
-
|
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
|
Pollution Degree
3
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
Main output 110-150% of rated normal voltage, Latch mode
|
|
Overload / Overcurrent
Main output 105-130% of rated current, Hiccup Mode
|
|
Over Temperature
Latch Mode
|
|
Short Circuit
Hiccup Mode (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC62368-1 CB report
TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 IEC60335-1 CB report IEC61558-1 /-2-16 CB report |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
|
|
Medical Safety
IEC60601-1 CB report
TUV EN60601-1 ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1 |
|
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground (1XMOPP): 1768 Vac Output to/Ground (1XMOPP): 1768 Vac (Type BF application rated) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 (UK MDR 2002)
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
EN55032 Class B, AS/NZS CISPR32 Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC 61000-3-2, Meet Class A limit
|
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
IEC 61000-4-11
IEC 60601-1-2 |
|
Component Power Supply for General Use
-
|
24V
600W
25A
85-264Vac
24V
650W
0-27.1A
90-264 Vac
24V
200W
0-8.34A
90-264 Vac
24V
200W
0-8.34A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.