Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
600W
25A
85-264Vac
203.2 x 127 x 40 mm
8.00” x 5.00” x 1.57”
1.30 kg (2.87 lb)
24V
600W
25A
85-264Vac
203.2 x 127 x 40 mm
8.00” x 5.00” x 1.57”
1.30 kg (2.87 lb)
|
Output Current
25A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
600W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
1%
|
|
Load Regulation
2%
|
|
PARD
-
|
|
Start-up Time
2000ms @ 115Vac
|
|
Hold-up Time
20ms @ 600W, with nominal input range
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 50-100% load change
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
<50ms
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
7.5A
|
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
92.5% @ 115Vac/60Hz
93.5% @ 230Vac/50Hz |
|
Inrush Current
55A @ 264Vac, cold/hot start
|
|
Charging Time
-
|
|
Power Factor at 100% load
0.95 @ 115V/50Hz, 230V/50Hz, full load
|
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
-
|
|
|
Indicator
-
|
|
|
Cooling System
-
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
1.30 kg (2.87 lb)
|
Dimensions
203.2 x 127 x
40 mm
8.00” x 5.00” x 1.57” |
|
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
Absolute Maximum/Minimum Rating -20°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Linear power derate from 100% load at 50°C, to 50% load at 70°C
|
|
Operating Humidity
5-95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Overvoltage
(max)
Main output 140% of rated normal voltage, Latch Mode Standby 125% of rated voltage, Latch Mode |
|
Overload / Overcurrent
(max)
Main output 160% of rated current Standby 2A max Hiccup Mode(Non-Latching, Auto-Recovery) Fan Output 1.5A max with current limiting protection |
|
Over Temperature
Latch Mode for Main output
|
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
(Minimum) at 115Vac, Full Load, 35 °C
500 Khrs based on Telecordia SR-332 |
|
Expected Cap Life Time
-
|
|
Safety Certificate
IEC 60601-1 CB report
TUV EN 60601-1 A11/A12 UL 60601-1+CAN/CSA 60601-1 IEC 60950-1, IEC 62368-1 CB report TUV EN 60950-1, EN 62368-1 UL 60950-1+CAN/CSA 60950-1, UL 62368-1+CAN/CSA 62368-1 |
|
Electrical Safety
IEC60950-1, IEC62368-1 CB report
TUV EN60950-1, EN62368-1 UL60950-1+CAN/CSA60950-1, UL62368-1+CAN/CSA62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
|
|
Medical Safety
IEC 60601-1 CB report
TUV EN60601-1 UL 60601-1+CAN/CSA 60601-1 |
|
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500 Vac Output to/Ground(1XMOPP): 1500 Vac ( Type BF application rated) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016, and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002)
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
EN/BS EN 55011, EN/BS EN 55032, Class B
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC61000-3-2: Meet Class D limit
|
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
501.6W
0-20.9A
85-264 Vac
48V
100.8W
2.1A
85-264Vac
48V
153.6W
3.2A
85-264Vac
12V
102W
8.5A
85-264Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.