Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V
500.4W
0-41.7A
85-264 Vac
127.0 x 76.2 x 33.1 mm
5.00” x 3.00” x 1.30”
0.41 kg (0.90 lb)
12V
500.4W
0-41.7A
85-264 Vac
127.0 x 76.2 x 33.1 mm
5.00” x 3.00” x 1.30”
0.41 kg (0.90 lb)
Output Current
0-41.7A
|
Output Voltage
12V
|
Output Voltage Range
|
Output Voltage Adjustment Range
10.8-13.2 Vdc
|
Output Power
500.4W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
0.5%
|
Load Regulation
1%
|
PARD
80 mV
|
Start-up Time
1000 ms @ 115 Vac & 230 Vac
|
Hold-up Time
13 ms typ. @ 115 Vac & 230 Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ with 5-100% load change,
(50% duty @ 5 Hz & 10 KHz, 2.5 A/us slew rate) |
Start-up with Capacitive Loads
8,000 μF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
100 ms typ. @ 115 Vac & 230 Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Peak Power
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
85-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
6.5 A typ. @ 115 Vac, 4.0 A typ. @ 230 Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
91% type @ 115 Vac
94% typ. @ 230 Vac |
Inrush Current
60 A typ. @ 230 Vac (Cold Start)
|
Charging Time
-
|
Power Factor at 100% load
> 0.99 @ 115 Vac
> 0.94 @ 230 Vac |
Leakage Current
0.1 mA @ NC,
5.0 mA @ SFC |
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Open Frame
|
|
Indicator
-
|
|
Cooling System
Convection / Force air
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
Input: JST: B2P3-VH(LF)(SN) or equivalent
Output: M4 x 0.7 Control: HIROSE: DF1BZ-4DP-2.5DSA or equivalent Control: HIROSE: DF1BZ-4DP-2.5DS or equivalent JST : B2B-EH-A(LF)(SN) or equivalent (only 12V for DC FAN) JST : S2B-EH(LF)(SN) or equivalent (for DC FAN) |
|
Unit Weight
0.41 kg (0.90 lb)
|
Dimensions
127.0 x 76.2 x
33.1 mm
5.00” x 3.00” x 1.30” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-30 °C to +85 °C (-40 °C Cold Start)
|
Storage Temperature
-40 °C to +85 °C
|
Power De-rating
Temperature Power De-rating: > 50°C de-rate power by 1.43% / °C
Line Power De-rating: < 115 Vac de-rate power by 0.67% / Vac |
Operating Humidity
10-95 % RH (Non-Condensing)
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
5-500 Hz, 2.09 Grms, 20 minutes for each three axis
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
|
Pollution Degree
3
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Corrosion
-
|
Acoustic Noise
-
|
Overvoltage
Main output 105-150% of rated normal voltage, Latch mode
|
Overload / Overcurrent
Main output 105-185% of rated current, Hiccup Mode
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I / II
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
-
|
Electrical Safety
IEC 62368-1 CB report
TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 IEC60335-1 CB report IEC61558-1 /-2-16 CB report |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
Medical Safety
IEC 60601-1 CB report
TUV EN60601-1 ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1 |
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground (1XMOPP): 2500 Vac Output to/Ground (1XMOPP): 1500 Vac (Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN55032 Class B, AS/NZS CISPR32 Class B
Note: Class A Radiated Emission and Conducted Emission for Class II connection without earth connection |
Immunity
-
|
Harmonic Current Emissions
IEC 61000-3-2, Meet Class D limit
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
IEC 61000-4-11
IEC 60601-1-2 |
Component Power Supply for General Use
-
|
48V
504W
-
85-264 Vac
18V
500.4W
-
85-264 Vac
24V
501.6W
-
85-264 Vac
24V
600W
-
90-264 Vac