Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
15V
25W
1.67A
90-264 Vac
76.2 x 50.8 x 23 mm
3.00” x 2.00” x 0.91”
0.07 kg (0.15 lb)
15V
25W
1.67A
90-264 Vac
76.2 x 50.8 x 23 mm
3.00” x 2.00” x 0.91”
0.07 kg (0.15 lb)
|
Output Current
1.67A
|
|
Output Voltage
15V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
25W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
0.5%
|
|
Load Regulation
1%
|
|
PARD
100 mVpp (20 MHz)
|
|
Start-up Time
2000 ms @ 115 Vac
1000 ms @ 230 Vac |
|
Hold-up Time
24ms @ 115Vac, 115ms @ 230Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 3% @ with 50-100% load change, (50% duty @ 5 Hz & 10 KHz, 2.5 A/us slew rate )
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
25 W
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
30ms @ 115Vac & 230Vac (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240 Vac
|
|
Input Voltage Range
90-264 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
0.6 A @ 115 Vac
0.4 A @ 230 Vac |
|
Input Power (Standby Mode)
0.21 W @ 115 Vac & 230 Vac
|
|
Efficiency at 100% load
85.7% @ 115 Vac
86.5% @ 230 Vac |
|
Inrush Current
35 A @ 230 Vac, cold start
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
0.15 uA @ NC, 0.3 uA @ SFC
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
Open Frame
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
JST, B2P3-VH(LF)(SN) or equivalent
|
|
|
Output Terminal
JST : B4P-VH(LF)(SN) or equivalent
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 25 dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.07 kg (0.15 lb)
|
Dimensions
76.2 x 50.8 x
23 mm
3.00” x 2.00” x 0.91” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Temperature Power De-rating: Linear power derating from 100% load at 50°C to 50% load at 70°C with 2.5%/°C
|
|
Operating Humidity
10-95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
5-500 Hz, 2.09 Grms, 20 minute for each three axis
|
|
Storage Humidity
-
|
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
II
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
150%, Latch mode
|
|
Overload / Overcurrent
Main output 150~210% of rated load current , Hiccup Mode
|
|
Over Temperature
Hiccup Mode
|
|
Short Circuit
Hiccup Mode (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class II
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Safety Certificate
-
|
|
Electrical Safety
-
|
|
CE
In conformance with Low Voltage Directive 2014/35/EU,
MDD Directive 93/42/EEC EN 60601-1: 2006 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
|
Medical Safety
IEC60601-1 CB report, ANSI/AAMI ES60601-1,
TUV EN60601-1 ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1 |
|
Galvanic Isolation
Input to/Output (2XMOPP: 4000 Vac
Input to/Ground (1XMOPP): 2000 Vac Output to/Ground(1XMOPP): 1500 Vac (Type BF application rated) |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
IEC 62368-1 CB report
GB 4943.1, GB/T 9254.1, GB17625.1 |
|
SIL3
-
|
12V
150W
12.5A
85-264Vac
12V
102W
8.5A
85-264Vac
12V
500.4W
-
85-264 Vac
24V
600W
-