Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
12V
150W
12.5A
85-264Vac
188 x 85 x 47 mm
7.40” x 3.35” x 1.85”
0.46 kg (1.01 lb)
12V
150W
12.5A
85-264Vac
188 x 85 x 47 mm
7.40” x 3.35” x 1.85”
0.46 kg (1.01 lb)
|
Output Current
12.5A
|
|
Output Voltage
12V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
10.8-13.2Vdc
|
|
Output Power
150W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
+/- 0.5%
|
|
Load Regulation
+/- 0.5%
|
|
PARD
-
|
|
Start-up Time
500ms typ. @ 100Vac
|
|
Hold-up Time
30 ms typ. @ 100 Vac (100% load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 & 230 Vac input, 10-100% load
(Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz) |
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
120-373 Vdc
|
|
Input Current
1.90A typ. @ 100Vac,
0.95A typ. @ 200Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
88.0% typ. @ 100Vac,
91.5% typ. @ 200Vac |
|
Inrush Current
15A typ. @ 100Vac,
30A typ. @ 200Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
0.98 typ. @ 100Vac, 0.95 typ. @ 200Vac
|
|
Leakage Current
0.2mA @ 100Vac,
0.4mA @ 240Vac |
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
SGCC
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
JST B3P5-VH (LF)(SN)
|
|
|
Output Terminal
V–: JST B7P-VH (LF)(SN), V+: JST B6P-VH (LF)(SN)
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
AWG 22-18
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.46 kg (1.01 lb)
|
Dimensions
188 x 85 x
47 mm
7.40” x 3.35” x 1.85” |
|
Vibration (Operating)
IEC 60068-2-6, Sine Wave:10 Hz to 500 Hz @ 2G; 10 min period,
60 min per axis for all X, Y, Z direction |
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to +70°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
Refer to Engineering Data Fig.1.1~Fig.1.5 on Page7~9
|
|
Operating Humidity
5 to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave 50G,11 ms, 3 shocks X, Y, and Z direction
|
|
Vibration (Non-Operating)
-
|
|
Storage Humidity
-
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
14.0-18.0V, Latch Mode
|
|
Overload / Overcurrent
> 201% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
Latch Mode
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
|
|
Expected Cap Life Time
10 years (115Vac, 50% load @ 40°C)
|
|
Case Temperature Rise
-
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart: EN 62368-1
UL/cUL Recognized: UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1 Design to meet DENAN at 100 Vac |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 2.0 KVac Output to Ground: 1.25 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
CISPR 32, EN/BS EN 55032, Comply with FCC Title 47: Class B
|
|
Immunity
EN/BS EN 55024
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A & Class D
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
501.6W
0-20.9A
85-264 Vac
48V
504W
0-10.5A
85-264 Vac
15V
25W
1.67A
90-264 Vac
48V
100.8W
2.1A
85-264Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.