Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
150W
6.25A
85-264Vac
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.48 kg (1.06 lb)
| Model | Description |
|---|---|
| PMC-24V150W1AJ | IP20 connector |
24V
150W
6.25A
85-264Vac
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.48 kg (1.06 lb)
| Model | Description |
|---|---|
| PMC-24V150W1AJ | IP20 connector |
|
Output Current
6.25A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
22-28Vdc
|
|
Output Power
150W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
< 0.5% typ. (@ 85-264Vac input, 100% load)
|
|
Load Regulation
< 1% typ. (@ 85-264Vac input, 0-100% load)
|
|
PARD
< 100mVpp
|
|
Start-up Time
< 1000ms @ nominal input (100% load)
|
|
Hold-up Time
> 15ms @ 115Vac,
> 80ms @ 230Vac (100% load) |
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264 Vac input, 0-100% load
(Slew Rate: 0.1 A/μs, 50% duty cycle @ 5 Hz to 1 KHz) |
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 30ms @ nominal input (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Nominal Input Voltage
100-240Vac
|
|
Input Voltage Range
85-264Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
125-250Vdc
|
|
DC Input Voltage Range
125-375Vdc
|
|
Input Current
< 3.1A @115Vac,
< 2.0A @230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 87% @ 115Vac,
> 88% @ 230Vac |
|
Inrush Current
< 60A @ 115Vac,
< 120A @ 230Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 1mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
<40dBA
|
|
|
Input/Output Terminal
PMC-24V150W1AA: M3.5 x 7 Pins (Rated 300V/15A)
PMC-24V150W1AJ: M3.5 x 7 Pins (Rated 300V/20A) |
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
PMC-24V150W1AA: AWG 18-14
PMC-24V150W1AJ: AWG 18-12 |
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.48 kg (1.06 lb)
|
Dimensions
178 x 97 x
38 mm
7.01” x 3.82” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% /°C
|
|
Operating Humidity
< 95% RH
|
|
Shock Test (Non-Operating)
IEC60068-2-27, 30G (300m/S²) for a duration of 18ms 3 times per direction, 18 times in total
|
|
Vibration (Non-Operating)
IEC60068-2-6, 10Hz to 500Hz @ 50m/S² (5G peak); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
3,000 Meters
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Overvoltage
< 32V ±10%, SELV output, Hicc-up Mode, Non-Latching (Auto recovery).
|
|
Overload / Overcurrent
> 120% of rated load current, Hicc-up Mode, Non-Latching (Auto recovery).
|
|
Over Temperature
< 75°C Ambient Temp@ 100% load, Non-Latching (Auto-recovery).
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-recovery when the fault is removed).
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs. per Telcordia SR-332
|
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart : EN 62368-1
UL/cUL recognized : UL 60950-1 and CSA C22.2 No. 60950-1, UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme :IEC 60950-1, IEC 62368-1 |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac Output to Ground: 500 Vac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
K 60950-1
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
Generic Standards: CISPR32, EN/BS EN 55032,
FCC Title 47: Class B |
|
Immunity
Generic Standards: EN/BS EN 55024
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
24V
1200W
0-50A
85-264 Vac
48V
750W
0-15.63A
85-264 Vac
24V
1500W
62.5A
90-264 Vac
48V
1500W
31.25A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.