Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
156W
6.5A
90-132Vac, 180-264Vac (Selectable by Switch)
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.48 kg (1.06 lb)
** NRND **
PMT-24V150W1AA,PMT-24V150W1AG, PMT-24V150W1AH, PMT-24V150W1AAB, PMT-24V150W1AAW
Recommended Model: PMT-24V150W2BA
| Model | Description |
|---|---|
| PMT-24V150W1AG | Enclosed, front face connector |
| PMT-24V150W1AH | Enclosed, harness connector |
| PMT-24V150W1AAB | Enclosed, terminal block, conformal coating |
** NRND **
PMT-24V150W1AA,PMT-24V150W1AG, PMT-24V150W1AH, PMT-24V150W1AAB, PMT-24V150W1AAW
Recommended Model: PMT-24V150W2BA
24V
156W
6.5A
90-132Vac, 180-264Vac (Selectable by Switch)
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.48 kg (1.06 lb)
| Model | Description |
|---|---|
| PMT-24V150W1AG | Enclosed, front face connector |
| PMT-24V150W1AH | Enclosed, harness connector |
| PMT-24V150W1AAB | Enclosed, terminal block, conformal coating |
|
Output Current
6.5A
|
|
Output Voltage
24V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
22.8-27.6Vdc
|
|
Output Power
156W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5% typ. (@ 100-132Vac & 200-264Vac)
|
|
Load Regulation
± 0.5% typ. (@ 100-132Vac & 200-264Vac)
|
|
PARD
< 120mVpp
|
|
Start-up Time
< 1200ms @ 115Vac, < 800ms @ 230Vac (100% load)
|
|
Hold-up Time
> 20ms @ 115Vac, > 24ms @ 230Vac
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load
|
|
Start-up with Capacitive Loads
8,000µF Max
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 30ms @ 115Vac, < 20ms @ 230Vac (100% load)
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-120Vac, 200-240Vac (Selectable by Switch)
|
|
Input Voltage Range
90-132Vac, 180-264Vac (Selectable by Switch)
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
< 3.00A @ 115Vac,
< 2.00A @ 230Vac |
|
Input Power (Standby Mode)
-
|
|
Efficiency at 100% load
> 89.0% typ. @ 230Vac
|
|
Inrush Current
< 45A @ 230Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
< 0.5mA @ 240Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Case Chassis / Cover
Aluminium / SGCC
|
|
|
Indicator
Green LED (DC OK)
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
-
|
|
|
Output Terminal
-
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.48 kg (1.06 lb)
|
Dimensions
178 x 97 x
38 mm
7.01” x 3.82” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +70°C
|
|
Storage Temperature
-25°C to +85°C
|
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 3% / 1V |
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms, 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
-
|
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
|
Pollution Degree
2
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Overvoltage
115-135%, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Overload / Overcurrent
110-150%, Hicc-up Mode, Non-Latching (Auto-Recovery)
|
|
Over Temperature
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Short Circuit
Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IPX0
|
|
Protection Against Shock
Class I with Primary Earth connection
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 100Vac, O/P: 100% load, Ta: 35°C |
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
TUV Bauart EN 60950-1, EN 62368-1
UL/cUL recognized UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) CB scheme IEC 60950-1, IEC 62368-1 BIS IS 13152-1 BIS IS 13252 (Part 1) (for PMT-24V150W1AA) CCC GB 4943.1 (for PMT-24V150W1AA) |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
|
Medical Safety
-
|
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac Output to Ground: 0.5 KVac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
SELV
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, FCC Title 47: Class B |
|
Immunity
EN/BS EN 55024
|
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
36V
1000W
28A
90-264 Vac
48V
1000W
21A
90-264 Vac
12V
2500W
0-208.3A
85-264 Vac
48V
108W
2.3A
180-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.