Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
15V
90W
6A
90-264 Vac
135 x 62 x 32 mm
5.31” x 2.44” x 1.26”
0.31 kg (0.68 lb)
| Model | Description |
|---|---|
| MEA-090A15C 6-A | C14, 4 Pin DIN |
| MEA-090A15C V-A | C14, tuning fork 90° |
| MEA-090A15C W-A | C14, tuning fork |
15V
90W
6A
90-264 Vac
135 x 62 x 32 mm
5.31” x 2.44” x 1.26”
0.31 kg (0.68 lb)
| Model | Description |
|---|---|
| MEA-090A15C 6-A | C14, 4 Pin DIN |
| MEA-090A15C V-A | C14, tuning fork 90° |
| MEA-090A15C W-A | C14, tuning fork |
|
Output Current
6A
|
|
Output Voltage
15V
|
|
Output Voltage Range
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
90W
|
|
Output Current Adjustment Range
|
|
Max Output Voltage
|
|
Buffering Time
-
|
|
Line Regulation
± 0.5%
|
|
Load Regulation
± 4.5%
|
|
PARD
-
|
|
Start-up Time
< 3000 ms @ 115 Vac & 230 Vac
|
|
Hold-up Time
20 ms @ 115 Vac & 230 Vac
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-50% & 50-100% load; Slew rate 0.25 A/µs (@ 100 Hz, 50% Duty Cycle)
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
1%
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
< 50 ms @ 115 Vac & 230 Vac
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
100-240 Vac
|
|
Input Voltage Range
90-264 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
1.5 A @ 115 Vac, 0.75 A @ 230 Vac
|
|
Input Power (Standby Mode)
0.15 W @ 115 Vac & 230 Vac
|
|
Efficiency at 100% load
-
|
|
Inrush Current
50 A @ 115 Vac and 100 A @ 230 Vac
|
|
Charging Time
-
|
|
Power Factor at 100% load
-
|
|
Leakage Current
0.1 mA @ 264 Vac NC1), 0.5 mA @ 264 Vac Single fault condition
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Case Chassis / Cover
PC
|
|
|
Indicator
Green LED
|
|
|
Cooling System
-
|
|
|
Input Terminal
IEC 60320 C14 socket
|
|
|
Output Terminal
Tuning Fork type: 5.5 x 2.5 x 11 mm, 90° (for MEA-090A□C V-A)
4 Pin Din type, 180° (for MEA-090A□C 6-A) Tuning Fork type: 5.5 x 2.5 x 11 mm, 180° (for MEA-090A□C W-A) |
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
-
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
0.31 kg (0.68 lb)
|
Dimensions
135 x 62 x
32 mm
5.31” x 2.44” x 1.26” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-10°C to +60°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
> 40°C de-rate power by 2.5% / °C
|
|
Operating Humidity
5-95% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
|
Vibration (Non-Operating)
5-500 Hz, 2.09 Grms, 20 minute for each three axis
|
|
Storage Humidity
-
|
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa)
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
150% max, Latch Mode
|
|
Overload / Overcurrent
180% max of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery)
|
|
Over Temperature
Latch Mode
|
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP22
|
|
Protection Against Shock
Class I with C14 socket
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
MTBF
> 1 million Hours based on Telecordia SR-332 (at 115Vac, Max. load and 25°C Ambient)
|
|
Expected Cap Life Time
5 years (50% load @ 115Vac, 25°C)
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 62368-1
IEC 60950-1 GB4943.1-2011, GB9254-2008, GB17625.1-2012 PSE J60950-1(H29) |
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
|
Medical Safety
IEC 60601-1 CB report, EN 60601-1
CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1 |
|
Galvanic Isolation
Input to Output : 4000 Vac
Input to PE3) : 1500 Vac Output to PE3): 500 Vac |
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
RoHS Directive 2011/65/EU & EU 2015/863 Compliant
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016,
Medical Devices Regulations 2002 (UK MDR 2002) |
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
IEC 62368-1
IEC 60950-1 GB4943.1, GB9254, GB17625.1 PSE J60950-1(H29) |
|
SIL3
-
|
|
Emission
EN/BS EN 55011, EN/BS EN 55032 Class B
Compliance to FCC Title 47: Class B |
|
Immunity
-
|
|
Harmonic Current Emissions
IEC 61000-3-2 Meet Class A
|
|
Voltage Fluctuation and Flicker
-
|
|
ESD Immunity
-
|
|
Radiated Immunity
-
|
|
EFT
-
|
|
Surge
-
|
|
Conducted Immunity
-
|
|
Magnetic Field
-
|
|
Voltage Dips
-
|
|
Component Power Supply for General Use
-
|
5V,9V,12V,15V,20V
30W
3A,3A,2.5A,2A,1.5A
90-264 Vac
5V,9V,15V,20V
65W
3A,3A,3A,3.25A
90-264 Vac
5V,9V,15V,20V
45W
3A,3A,3A,2.25A
90-264 Vac
24V
300W
12.5A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.