Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24-54V
20W
0.7A
198-264Vac
147.0 x 43.0 x 30.0 mm
5.79” x 1.69” x 1.18”
0.19 kg (0.42 lb)
** NRND **
Model | Description |
---|---|
EUCI-020070GLAB | Built-in type |
** NRND **
24-54V
20W
0.7A
198-264Vac
147.0 x 43.0 x 30.0 mm
5.79” x 1.69” x 1.18”
0.19 kg (0.42 lb)
Model | Description |
---|---|
EUCI-020070GLAB | Built-in type |
Output Current
0.7A
|
Output Voltage
24-54V
|
Output Voltage Range
24-54Vdc
|
Output Voltage Adjustment Range
-
|
Output Power
20W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 1%
|
Load Regulation
± 5%
|
PARD
-
|
Start-up Time
< 200ms @ 230Vac
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 100ms @ 230Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Peak Power
-
|
Nominal Input Voltage
220-240Vac
|
Input Voltage Range
198-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50/60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
220-240Vdc
|
DC Input Voltage Range
176-280Vdc
|
Input Current
-
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
86% typ. @ 230Vac
|
Inrush Current
-
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 230Vac/50Hz
|
Leakage Current
< 0.7mA @ 230Vac
|
Nominal Current
-
|
Total Harmonic Distortion
< 15% @ 230Vac/50Hz at 100% load
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Plastic
|
|
Indicator
-
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.19 kg (0.42 lb)
|
Dimensions
147.0 x 43.0 x
30.0 mm
5.79” x 1.69” x 1.18” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-25°C to +50°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
10 to 60% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
-
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Acoustic Noise
-
|
Overvoltage
Max. 60V, Auto-Recovery when the fault is removed
|
Overload / Overcurrent
-
|
Over Temperature
Auto-Recovery when the fault is removed
|
Short Circuit
Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
500,000 hrs.@ta: +50°C (as per Telcordia SR-332 , total failure rate less than 10% )
|
Expected Cap Life Time
50,000 hrs. at lifetime case temperature
|
Safety Certificate
-
|
Electrical Safety
Class II (Built-in type, without kits)
Class II, Independent lamp control gear (Independent type, with kits) SELV EL CB scheme to IEC 61347-1, IEC 61347-2-13 ENEC to EN 61347-1, EN 61347-2-13 |
CE
In conformance with EMC Directive and Low Voltage Directive
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Compliance to EN 55015 Class B
|
Immunity
Compliance to EN 61547
|
Harmonic Current Emissions
IEC 61000-3-2, Class C (230Vac @ 100% load)
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
200-550V
600W
2A
198-440Vac
35-105V
75W
0.2-1.05A
198-264Vac
60-200V
130W
0.2-1.05A
198-264Vac
150-550V
1200W
2A
187-528 Vac