Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
150-550V
1800W
1A
180-528 Vac
345 x 152 x 62 mm
13.58” x 5.98” x 2.44”
5.4 kg (11.90 lb)
150-550V
1800W
1A
180-528 Vac
345 x 152 x 62 mm
13.58” x 5.98” x 2.44”
5.4 kg (11.90 lb)
|
Output Current
1A
|
|
Output Voltage
150-550V
|
|
Output Voltage Range
150-550Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
1800W
|
|
Output Current Adjustment Range
0.7-2A
|
|
Max Output Voltage
600Vdc
|
|
Buffering Time
-
|
|
Line Regulation
-
|
|
Load Regulation
-
|
|
PARD
-
|
|
Start-up Time
-
|
|
Hold-up Time
-
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
200-480 Vac
|
|
Input Voltage Range
180-528 Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50/60 Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
7.2A at 220Vac, 25°C, 1500W output
4.0A At 480Vac, 25°C, 1800W output |
|
Input Power (Standby Mode)
0.5W at 230Vac/50Hz, Dim OFF,
in compliance with Erp(EU) 2019/2020 |
|
Efficiency at 100% load
97% at 220Vac, Io=3A @ Pout=1500W
98.05% at 400Vac, Io=3.27A @ Pout=1800W |
|
Inrush Current
14A at 220Vac,10%Ipeak to 10% Ipeak: <5 ms
25A at 480Vac,480Vac, 10%Ipeak to 10% Ipeak: <5ms compliant with NEMA410-2015 |
|
Charging Time
-
|
|
Power Factor at 100% load
0.99 typ. at 220Vac/50Hz, Pout=1500W
0.99 typ. at 400Vac/50Hz, Pout=1800W |
|
Leakage Current
-
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
10% at 220Vac/50Hz, Pout=1500W output
15% at 400Vac/50Hz, Pout=1800W |
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
Aluminum alloy case, dark gray
|
|
|
Indicator
-
|
|
|
Cooling System
Natural Convection
|
|
|
Input Terminal
L1/L, L2/N, PE
|
|
|
Output Terminal
PE, V+, V-, NTC,
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
5.4 kg (11.90 lb)
|
Dimensions
345 x 152 x
62 mm
13.58” x 5.98” x 2.44” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40 ~+50°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10% to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
-
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
|
|
Storage Humidity
5% to 95% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
-
|
|
Overload / Overcurrent
-
|
|
Over Temperature
-
|
|
Short Circuit
-
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
IP66
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
MTBF
475khrs. at Ta=+45°C Telcordia SR-332
|
|
Expected Cap Life Time
50,000 hours applicable for 277Vac to 480Vac(50/60Hz)@ 1800W and
220 to 240Vac(50Hz)@ 1500W, Ta=45℃(Tcase=80℃), |
|
Case Temperature Rise
-
|
|
Safety Certificate
ENEC:
EN 61347-2-13:2015, EN 61347-1-2015/A1:2021 EN 61347-2-13:2014, EN 61347-2-13:2014/A1:2017 EN IEC 62384:2020 CB report: EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN 61347-1:2015/AMD1:2017 IEC 61347-2-13:2014, IEC 61347-2-13:2014/AMD1:2016 UL8750 2nd Ed., CSA C22.2 No.250.13, 5th Ed. RCM: AS/NZS 61347.1:2016+A1, AS 61347.2.13:2018 CCC: GB 19510.1, GB 19510.14 |
|
Electrical Safety
-
|
|
CE
CE Declaration of Conformity.
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
BS EN 61347-2-13: 2014+A1:2017
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
Radiated Emission EN55015, GB/T17743, FCC 47CFR Part 15 Subpart B, Class B, ANSI C63.4, ICES-005
|
|
Immunity
-
|
|
Harmonic Current Emissions
IEC 61000-3-2, GB 17625.1
|
|
Voltage Fluctuation and Flicker
EN61000-3-3
|
|
ESD Immunity
EN 61000-4-2, IEC/EN 61547
|
|
Radiated Immunity
-
|
|
EFT
EN 61000-4-4
|
|
Surge
(AC Mains)
IEC 61000-4-4, IEC/EN 61547 |
|
Conducted Immunity
-
|
|
Magnetic Field
EN 61000-4-3, IEC/EN 61547
|
|
Voltage Dips
EN 61000-4-11, IEC/EN 61547
|
|
Component Power Supply for General Use
-
|
200-550V
600W
2A
198-440Vac
80-310V
170W
0.2-1.05A
198-264Vac
24V
150W
6.25A
108-264 Vac
150-550V
1400W
2A
198-440 Vac