Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
60-152V
320W
1.4-2.8A
99-305Vac
240 x 100 x 38 mm
9.45” x 3.94” x 1.50”
1.8kg (3.97 lb)
60-152V
320W
1.4-2.8A
99-305Vac
240 x 100 x 38 mm
9.45” x 3.94” x 1.50”
1.8kg (3.97 lb)
|
Output Current
1.4-2.8A
|
|
Output Voltage
60-152V
|
|
Output Voltage Range
60-152Vdc
|
|
Output Voltage Adjustment Range
-
|
|
Output Power
320W
|
|
Output Current Adjustment Range
0.7-2.8A
|
|
Max Output Voltage
180Vdc
|
|
Buffering Time
-
|
|
Line Regulation
± 1% (@ 110-277Vac input)
|
|
Load Regulation
± 3% (@ Min-Max output voltage)
|
|
PARD
-
|
|
Start-up Time
500ms max. @ 110-277Vac (full load)
|
|
Hold-up Time
16ms typ. @ 110-277Vac (full load)
|
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
|
Start-up with Capacitive Loads
-
|
|
Remote ON/OFF
-
|
|
Protective Device
-
|
|
Voltage Drop Between Input and Output
-
|
|
Residual Ripple/PARD (20MHz)
-
|
|
Residual Ripple
-
|
|
Max. Power
-
|
|
Ripple & Noise
-
|
|
LED System Voltage Range in CC Mode
-
|
|
Rise Time
-
|
|
Power Boost Duration
-
|
|
Power Boost Recovery Time
-
|
|
Peak Power
-
|
|
Nominal Input Voltage
110-277Vac
|
|
Input Voltage Range
99-305Vac
|
|
Max Input Voltage
-
|
|
Nominal Input Frequency
50-60Hz
|
|
Input Frequency Range
47-63Hz
|
|
Nominal DC Input Voltage
|
|
DC Input Voltage Range
-
|
|
Input Current
3.4A
|
|
Input Power (Standby Mode)
0.5W @ Dim to off, 230Vac & 277Vac
|
|
Efficiency at 100% load
92.0%@2.1A @120Vac
94.0%@2.1A @230Vac 94.5%@2.1A @277Vac |
|
Inrush Current
90A/250uS @120Vac |
|
Charging Time
-
|
|
Power Factor at 100% load
> 0.98@110/120Vac,> 0.95 @ 230Vac,> 0.92 @ 277Vac&Full Load, > 0.90 @ 110/120/230Vac&> 50% Load(277Vac&> 70% Load )
|
|
Leakage Current
< 0.7mA peak @ 277Vac
|
|
Nominal Current
-
|
|
Total Harmonic Distortion
-
|
|
Power Dissipation
-
|
|
Efficiency @ 10% load
-
|
|
Input Voltage Phase
-
|
|
Average Efficiency
-
|
|
No Load Power Consumption
-
|
|
Case Chassis / Cover
Aluminum
|
|
|
Indicator
-
|
|
|
Cooling System
Convection
|
|
|
Input Terminal
Line: Brown, Neural: Blue, PE: Yellow/Green, Cable Length 300mm
|
|
|
Output Terminal
Positive: Brown, Negative: Blue, NTC/PRG: Black, Cable Length 300mm
|
|
|
Signal Terminal
-
|
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
|
Input/Output Terminal
-
|
|
|
Signal
-
|
|
|
Mounting Rail
-
|
|
|
Wire
-
|
|
|
Protection Structure
-
|
|
|
Terminal
-
|
|
|
Unit Weight
1.8kg (3.97 lb)
|
Dimensions
240 x 100 x
38 mm
9.45” x 3.94” x 1.50” |
|
Vibration (Operating)
-
|
|
Shock Test (Operating)
-
|
|
Operating Temperature
-40°C to +50°C
|
|
Storage Temperature
-40°C to +85°C
|
|
Power De-rating
-
|
|
Operating Humidity
10 to 90% RH (Non-Condensing)
|
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
|
|
Storage Humidity
5 to 95% RH (Non-Condensing)
|
|
Operating Altitude
-
|
|
Pollution Degree
-
|
|
Bump Test (Operating)
-
|
|
Over Voltage Category
-
|
|
Corrosion
-
|
|
Acoustic Noise
-
|
|
Shock
-
|
|
Vibration
-
|
|
Overvoltage
180Vrms, Auto-Recovery when the fault is removed
|
|
Overload / Overcurrent
Reduce output current. Auto-Recovery when the fault is removed
|
|
Over Temperature
Reduce output current. Auto-Recovery when the fault is removed
|
|
Short Circuit
Auto-Recovery when the fault is removed
|
|
Reverse Polarity Protection
-
|
|
Degree of Protection
-
|
|
Protection Against Shock
-
|
|
Input Polarity Protection
-
|
|
Battery Polarity Protection
-
|
|
Wrong Battery Voltage Protection
-
|
|
Deep Discharge Protection
-
|
|
Overload
-
|
|
Overcurrent
-
|
|
Internal Fuse
-
|
|
Insufficient Input Voltage Protection
-
|
|
Pollution Degree
-
|
|
Safety Certificate
-
|
|
Electrical Safety
IEC 61347-1, IEC 61347-2-13 (independent)
EN 61347-1, EN 61347-2-13 UL 8750, type “HL” & type “TL” UL 60950-1 and CSA C22.2 No. 60950-1 SELV for 75W |
|
CE
In conformance with EMC Directive and Low Voltage Directive
|
|
Medical Safety
-
|
|
Galvanic Isolation
-
|
|
Industrial Control Equipment
-
|
|
Hazardous Location / ATEX
-
|
|
II 3 G ATEX 2014/34/EU
-
|
|
Electrical Equipments of Machines
-
|
|
Electrical Equipment for Use in Electrical Power Installations
-
|
|
Safety Entry Low Voltage
-
|
|
Maritime
-
|
|
Material and Parts
-
|
|
Isolation Resistance
-
|
|
PE Resistance
-
|
|
UKCA
-
|
|
Certificates for Other Countries
-
|
|
BIS
-
|
|
KC
-
|
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
|
ITE Safety
-
|
|
SIL3
-
|
|
CE/UKCA
-
|
|
Emission
Compliance to EN 55015 Class B; 47 CFR FCC Part 15, Subpart B, Class B
|
|
Immunity
Compliance to EN 61547
|
|
Harmonic Current Emissions
IEC 61000-3-2 Class C (230Vac @ ≥ 50% load)
|
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
|
ESD Immunity
IEC 61000-4-2
|
|
Radiated Immunity
IEC 61000-4-3
|
|
EFT
IEC 61000-4-4
|
|
Surge
IEC 61000-4-5
|
|
Conducted Immunity
IEC 61000-4-6
|
|
Magnetic Field
IEC 61000-4-8
|
|
Voltage Dips
IEC 61000-4-11
|
|
Component Power Supply for General Use
-
|
24V
96W
4A
108-305Vac
150-550V
1800W
1A
180-528 Vac
24V
150W
6.25A
90-266Vac
200-550V
600W
2A
198-440Vac